MOUNTING THE ACS7106
Make sure that you use appropriate screws when
securing the ACS7106.
In UL294 installations, #8 self-tapping screws can be
used to mount the ACS7106. Use one or two screws on
each side to mount the ACS7106.
Example of ACS7106 Mounted to Panel/Wall
GROUNDING THE ACS7106
The ACS7106 must be tied to earth ground to ensure
the system meets EMC/EMI requirements.
Using a screw driver, loosen the earth ground screw
on the side of the ACS7106 and then tighten the screw
after the earth ground wire (12-14AWG) is connected.

SETTING THE DIP SWITCHES

The ACS7106 has a 6-pin DIP switch located on the side
panel to configure the alarm relay output. This table
shows the DIP switch mapping to the corresponding
PoE and Gigabit ports.
DIP Switch
PoE Ports
1-4 (DIPs 1-4)
Gigabit Ports
5-6 (DIPs 5-6)
NOTE: If a port is not connected, make sure that the
corresponding DIP switch remains in the OFF position
so that the alarm is not activated.
mounting brackets
Setting
On
Off (Default) Disables the alarm for the
On
Off (Default) Disables the alarm for the
- 5 -
Description
Enables the alarm for the
corresponding PoE port
corresponding PoE port
Enables the alarm for the
corresponding Gigabit port
corresponding Gigabit port