WIRING THE POWER INPUTS
The power supply input range is 12-24VDC with a
maximum power consumption of 8W without PoE PD
loading.
Wiring methods shall be compliant with National
Electrical Code/NFPA 70/ANSI.
NOTE: Power should be disconnected from the power
supply before connecting it to the switch. Otherwise, your
screwdriver blade can inadvertently short your terminal
connections to the grounded enclosure.
1. Disconnect the power terminal block from the ACS7106.
2. Insert the positive and negative wires into PWR+ and
PWR- contacts.
3. Tighten the wire-clamp screws to prevent the wires from
being loosened.
NOTES:
• For UL installations, the ACS7106 is intended to be used
with a regulated UL Listed Class 2 or LPS (Limited Power
Supply).
• For the highest specified PoE output load, the ACS 7106
is intended to be used with a regulated UL Listed Class 2
or LPS rated at:
• 24VDC @ 4.8A or 12VDC @ 6.8A, minimum.
(UL60950 Installation)
• 24VDC @ 4.5A or 12VDC @ 6.8A, minimum.
(UL294 Installation)
WIRING THE ALARM RELAY OUTPUT
The alarm relay output or digital output (DO) contacts are
on the terminal block connector. The alarm relay output
contacts are normally open. The alarm relay output
contacts close when the alarm is enabled with the DIP
switches and there is a port link failure or PoE failure on a
port.
NOTE: The alarm relay is not intended to be an indication of
a burglary alarm condition.
The alarm relay output contacts support up to 1A at
24VDC. Do not apply voltage and current higher than the
specifications.
The alarm relay output is controlled by the
pre-defined operating rules. To activate the alarm relay
output function, refer to the Setting the DIP Switches
discussion.
PWR
-
+
12 - 24AWG Wires
*UL 294: A regulated UL294 approved power supply is required to meet
UL294 installation requirements.
Alarm Control
+
DIP Switch
Earth Ground
12 - 24AWG Wires
24VDC/1A
- 6 -
Wiring Positive Power Supplies
Power Supply
12 -24VDC
(UL Listed*)
v-
v
+
Alarm
PWR
Relay
Alarm Relay Output
Power
Source
Buzzer/PLC