Graco Reactor 2 H-30 Repair Manual page 31

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
T4DH
Hose
T4EA
Heater A
334946C
Type
Description
Type
Type
Description
Description
High Temperature
Hose
High Temperature
Switch A
Cause
Solution
Cause
Cause
Solution
Solution
Hose portion
Shade exposed hose from
exposed to an
hot sun or expose FTS to
excessive heat
same environment when
source, like hot
at rest. Uncoil entire hose
sun or coiled
before heating to avoid
hose, can pass
self-heating.
fluid more than
27°F (15°C) over
hose temperature
setting to the FTS.
Increase hose setpoint
Setting the A or
B setpoint much
so it is closer to A and B
higher than hose
setpoints.
setpoint can cause
fluid more than
27°F (15°C) over
hose temperature
setting to reach the
FTS.
Cold ambient
Cold ambient temperature
temperature is
is chilling the FTS and
causing hose to
causing hose heat to stay
heat
on longer than needed.
Insulate the FTS area of the
hose so that it heats at the
same rate as the rest of the
hose.
Overtemperature
Heater was delivered too
much power, causing the
switch sensed a
fluid temperature
overtemperature switch to
above 230°F
open. RTD is not reading
(110°C).
properly. After the heater
cools down, replace RTD.
Switch closes and the error
can be cleared when the
heater temperature falls
below 190°F (87°C).
Disconnected
If heater is not actually
or loose
over temperature, check
overtemperature
all wiring and connections
switch
between the TCM and the
cable/connection.
overtemperature switches.
Replace overtemperature
Overtemperature
switch failed in the
switch.
open position.
Troubleshooting
31