Graco Reactor 2 H-30 Repair Manual page 29

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
T3CH
Hose
T3CT
TCM
334946C
Type
Description
Type
Type
Description
Description
Hose Cutback
TCM Cutback
Cause
Solution
Cause
Cause
Solution
Solution
Hose current has
Hose setpoint higher than A
been reduced
and B setpoints. Decrease
because hose
hose setpoint.
has been drawing
Hose FTS is in a colder
current for an
environment than the rest
extended period.
of the hose. Expose FTS to
the same environment as
the rest of the hose.
High ambient
Ensure ambient
temperature.
temperature is below
120°F(48°C) before using
the system.
Enclosure fan not
Ensure fan in electrical
operating.
enclosure is spinning. If it
is not, check fan wiring or
replace fan.
Module fan not
If a TCM fan error (WMI0)
operating.
has occurred, fan inside
the module is not working
properly. Check TCM fan
for debris and clear with
forced air if necessary.