Graco Reactor 2 H-30 Repair Manual page 27

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
P7BX
HCM
T2DA
Heater A
334946C
Type
Description
Type
Type
Description
Description
Pressure Imbalance
B High
Low Temperature A
Cause
Solution
Cause
Cause
Solution
Solution
Pressure
Ensure material flow is
difference between
equally restricted on both
A and B material
material lines.
is greater than the
defined value.
Pressure
Ensure that the pressure
imbalance is
imbalance value, on the
defined too low.
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort dispenses.
Out of material.
Fill tanks with material
Fluid leaking from
Check if heater
heater inlet rupture
and PRESSURE
disk.
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
with a pipe plug.
Feed system
Check feed pump and
defective.
hoses for blockage. Check
that feed pumps have
correct air pressure.
Flow is too high at
Use a smaller mix chamber
current setpoint.
that is rated for the unit
in use. If recirculating,
decrease flow or decrease
temperature setpoint.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater.
see if issue follows. If so,
replace RTD.
Bad heater
Confirm resistance of
element.
heater. Heater resistance
should be 9-12 Ω for 10
kW systems and 6-8 Ω for
15 kW systems. If out of
tolerance, replace heater
element.
Loose heater
Check for loose heater
wires.
element wires.
Troubleshooting