Troubleshooting
Error
Location
Error
Error
Location
Location
P2FB
HCM
P4AX
HCM
P4BX
HCM
24
Type
Description
Type
Type
Description
Description
Low Inlet Pressure B
High Pressure A
High Pressure B
Cause
Solution
Cause
Cause
Solution
Solution
Inlet pressure
Ensure that inlet pressure
lower than defined
to the pump is sufficient.
value.
Value defined too
Ensure that the low
high.
pressure alarm level
defined on the System
Setup screen is acceptable.
System
Pressure in the hose and
pressurized before
pumps will increase as the
allowing heat to
system heats up. Turn on
reach setpoint.
heat and allow all zones
to reach the temperature
setpoint before turning on
the pumps.
Bad pressure
Verify the ADM pressure
transducer.
reading and the analog
gauges at the manifold.
Replace transducer if they
do not match.
H-XP2 or H-XP3
Alarm level is lower for
system configured
H-30, H-40 and H-50 than
as H-30, H-40, or
for H-XP2 and H-XP3..
H-50.
Ensure dial on HCM is set
to position "3" for H-XP2 or
"4" for H-XP3.
System
Pressure in the hose and
pressurized before
pumps will increase as the
system heats up. Turn on
allowing heat to
reach setpoint.
heat and allow all zones
to reach the temperature
setpoint before turning on
the pumps.
Bad pressure
Verify the ADM pressure
transducer.
reading and the analog
guages at the manifold.
H-XP2 or H-XP3
Alarm level is lower for
system configured
H-30, H-40 and H-50 than
as H-30, H-40, or
for H-XP2 and H-XP3..
H-50.
Ensure dial on HCM is set
to position "3" for H-XP2 or
"4" for H-XP3.
334946C