Graco Reactor 2 H-30 Repair Manual page 35

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Error
Location
Error
Error
Location
Location
V2MA
TCM
V2MB
TCM
V2MH
TCM
V3IT
TCM
V3MA
TCM
334946C
Type
Description
Type
Type
Description
Description
Low Voltage A
Low Voltage B
Low Voltage Hose
High Voltage CAN
High Voltage A
Cause
Solution
Cause
Cause
Solution
Solution
Loose connection
Check wiring for loose
or tripped circuit
connection or tripped circuit
breaker.
breaker.
Low incoming line
Measure voltage at circuit
voltage.
breaker and ensure voltage
is greater than 195 VAC.
Loose connection
Check wiring for loose
or tripped circuit
connection or tripped circuit
breaker.
breaker.
Low incoming line
Measure voltage at circuit
voltage.
breaker and ensure voltage
is greater than 195 VAC.
Loose connection
Check wiring for loose
or tripped circuit
connection or tripped circuit
breaker.
breaker.
Low incoming line
Measure voltage at circuit
voltage.
breaker and ensure voltage
is greater than 195 VAC.
Bad 24 VDC power
Check voltage of power
supply.
supply. Voltage should
be 23-25 VDC. If out of
tolerance, replace power
supply.
Incoming line
Ensure incoming system
voltage is too high.
power is wired properly.
Verify voltage at each circuit
breaker is between 195 and
264 VAC.
Troubleshooting
35