Troubleshooting
Error
Location
Error
Error
Location
Location
T2DB
Heater B
T2DH
Hose
T2FA
HCM
T2FB
HCM
28
Type
Description
Type
Type
Description
Description
Low Temperature B
Low Temperature
Hose
Low Temperature
Inlet A
Low Temperature
Inlet B
Cause
Solution
Cause
Cause
Solution
Solution
Flow is too high at
Use a smaller mix chamber
current setpoint.
that is rated for the unit
in use. If recirculating,
decrease flow or decrease
temperature setpoint.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater.
see if issue follows. If so,
replace RTD.
Bad heater
Confirm resistance of
element.
heater. Heater resistance
should be 9-12 Ω for 10
kW systems and 6-8 Ω for
15 kW systems. If out of
tolerance, replace heater
element.
Loose heater
Check for loose heater
wires.
element wires.
Flow is too high at
Use a smaller mix chamber
current setpoint.
that is rated for the unit
in use. If recirculating,
decrease flow or decrease
temperature setpoint.
Cold chemical in
Recirculate heated
unheated portion
chemical back to drum
of system passed
in cold conditions before
hose FTS at
startup.
startup.
Inlet fluid
Recirculate fluid through
temperature is
heaters until inlet fluid
below the defined
temperature is above
level.
defined error level.
Increase the low
temperature deviation
level on the System Setup
screen.
Inlet fluid
Recirculate fluid through
temperature is
heaters until inlet fluid
below the defined
temperature is above
level.
defined error level.
Increase the low
temperature deviation
level on the System Setup
screen.
334946C