Troubleshooting
Error
Location
Error
Error
Location
Location
T4CT
TCM
T4DA
Heater A
T4DB
Heater B
30
Type
Description
Type
Type
Description
Description
High Temperature
TCM
High Temperature A
High Temperature B
Cause
Solution
Cause
Cause
Solution
Solution
High ambient
Ensure ambient
temperature.
temperature is below
120°F(48°C) before using
the system.
Enclosure fan not
Ensure fan in electrical
operating.
enclosure is spinning. If it
is not, check fan wiring or
replace fan.
Module fan not
If a TCM fan error (WMI0)
operating.
has occurred, fan inside
the module is not working
properly. Check TCM fan
for debris and clear with
forced air if necessary.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater.
see if issue follows. If so,
replace RTD.
Flow too high
Use a smaller mix chamber
for temperature
that is rated for the unit in
setpoint, causing
use.
temperature
overshoots when
gun is de-triggered.
Bad RTD or bad
Swap A and B heater output
RTD placement
cables and RTD cables and
against heater.
see if issue follows. If so,
replace RTD.
Flow too high
Use a smaller mix chamber
for temperature
that is rated for the unit in
setpoint, causing
use.
temperature
overshoots when
gun is de-triggered.
334946C