4.6 CURSor Group
:CURSor:VERTical:PERDt?
Function
Queries the 1/∆ value (physical value) of the
horizontal axis between the V cursors.
Syntax
:CURSor:VERTical:PERDt?
Example
:CURSOR:VERTICAL:PERDT?→16.667E+00
:CURSor:VERTical:POSition<x>
Function
Sets the V cursor position or queries the current
setting.
Syntax
:CURSor:VERTical:POSition<x> {<time>|
<NRf>}
:CURSor:VERTical:POSition<x>?
<time> = 0 to (OBSERVATION TIME) (during
the normal measurement mode,
when Time Base = Internal)
<NRf> = 0 to Record length (when Time
Base = Internal, or during the
harmonic measurement mode)
Example
:CURSOR:VERTICAL:POSITION1 20MS
:CURSOR:VERTICAL:POSITION1?→:CURSOR:
VERTICAL:POSITION1 20.000E-03
Description
• The range and resolution of <time> depends
on the observation time.
• Specify <NRf> in terms of sampled data
points. The range is from 0 to the record
length.
:CURSor:VERTical:TRACe
Function
Sets the waveform on which to place the V
cursor or queries the current setting.
Syntax
:CURSor:VERTical:TRACe {<NRf>|MATH<x>}
:CURSor:VERTical:TRACe?
<NRf> = 1 to 8(channel)
<x> = 1, 2(MATH)
Example
:CURSOR:VERTICAL:TRACE 1
:CURSOR:VERTICAL:TRACE?→:CURSOR:
VERTICAL:TRACE 1
:CURSor:VERTical:X<x>?
Function
Queries the X-axis value (physical value) of the
V cursor position.
Syntax
:CURSor:VERTical:X<x>?
Example
:CURSOR:VERTICAL:X1?→20.000E-03
Description
The "
:CURSor:VERTical:POSition<x>?
command can be used to make the same
inquiry.
:CURSor:XY?
Function
Queries all settings related to XY cursor.
Syntax
:CURSor:XY?
Example
:CURSOR:XY?→:CURSOR:XY:
POSITION1 -25.0;POSITION2 25.0
4-22
:CURSor:XY:DX?
Function
Syntax
Example
:CURSor:XY:POSition<x>
Function
Syntax
Example
Description
:CURSor:XY:TRACe?
Function
Syntax
Example
Description
:CURSor:XY:X<x>?
Function
Syntax
Example
"
Queries the X-axis value (physical value)
between the XY cursors.
:CURSor:XY:DX?
:CURSOR:XY:DX?→150.00E+00
Sets the XY cursor position or queries the
current setting.
:CURSor:XY:POSition<x> {<NRf>}
:CURSor:XY:POSition<x>?
<NRf> = -100.0 to 100.0(%) (The
resolution is 0.1(%))
:CURSOR:XY:POSITION1 -25
:CURSOR:XY:POSITION1?→:CURSOR:XY:
POSITION1 -25.0
Set the value in terms of a percentage of the full
scale value displayed on the screen.
Queries the waveform on which the XY cursor
is placed.
:CURSor:XY:TRACe?
:CURSOR:XY:TRACE?→:CURSOR:XY:TRACE 1
The "
:DISPlay:XY:XTRace?
used to make the same inquiry.
Queries the X-axis value (physical value) of the
XY cursor position.
:CURSor:XY:X<x>?
:CURSOR:XY:X1?→-75.000E+00