4.1 Command Listing
Command
:MEASure:PERiod:ZCRoss[:SYNChronize]:ELEMent<x>
:MEASure:PHASe
:MEASure:SFORmula
NULL Group
:NULL
NUMeric Group
:NUMeric?
:NUMeric:FORMat
:NUMeric:HARMonics?
:NUMeric:HARMonics:CLEar
:NUMeric:HARMonics:ITEM<x>
:NUMeric:HARMonics:NUMber
:NUMeric:HARMonics:PRESet
:NUMeric:HARMonics:VALue?
:NUMeric:LIST?
:NUMeric:LIST:ITEM
:NUMeric:LIST:ORDer
:NUMeric:LIST:SELect
:NUMeric:LIST:VALue?
:NUMeric:NORMal?
:NUMeric[:NORMal]:CLEar
:NUMeric[:NORMal]:ITEM<x>
:NUMeric[:NORMal]:NUMber
:NUMeric[:NORMal]:PRESet
:NUMeric[:NORMal]:VALue?
SETup Group
:SETup?
:SETup:INITialize
:SETup[:MODE]
:SETup:PLLSource
:SETup:RESolution
:SETup:WIRing
SSTart Group
:SSTart
STARt Group
:STARt
STATus Group
:STATus?
:STATus:CONDition?
:STATus:EESE(Extended Event Status Enable register)
4-8
Function
Sets the synchronizing source for each element when using the zero crossing detection to
determine the computation period.
Sets the display format of the phase difference or queries the current setting.
Sets the equation used to determine S (apparent power) or queries the current setting.
Turns ON/OFF the NULL function or queries the current setting.
Queries all settings related to the numerical data output.
Sets the format of the numerical data that are sent using the "
" command or queries the current setting.
HARMonics|LIST}:VALue?
Queries all settings related to the numerical data output during harmonic measurement.
Clears the numerical data output items during harmonic measurement.
Sets the numerical data output items during harmonic measurement or queries the
current setting.
Sets the number of numerical data that are sent using the "
command or queries the current setting.
Sets the numerical data output items to a preset pattern during harmonic measurement.
Queries the numerical data during harmonic measurement.
Queries all settings related to the output of the numerical list data during harmonic
measurement.
Sets the output items of the numerical list data during harmonic measurement or queries
the current setting.
Sets the maximum harmonic order of the numerical list data to output during harmonic
measurement or queries the current setting.
Sets the output components of the numerical list data during harmonic measurement or
queries the current setting.
Queries the numerical list data during harmonic measurement.
Queries all settings related to the numerical data output during normal measurement.
Clears the numerical data output items during normal measurement.
Sets the numerical data output items during normal measurement or queries the current
setting.
Sets the number of numerical data during normal measurement or queries the current
setting.
Sets the numerical data output items to a preset pattern during normal measurement.
Queries the numerical data during normal measurement.
Queries all settings related to the measurement mode.
Initializes the settings.
Sets the measurement mode or queries the current setting.
Sets the PLL source during harmonic measurement or queries the current setting.
Sets the number of displayed digits for numerical data or queries the current setting.
Sets the wiring method or queries the current setting.
Executes single start.
Starts data acquisition.
Queries all settings related to the communication status function.
Queries the status register.
Sets the extended event enable register or queries the current setting.
:NUMeric:{NORMal|
:NUMeric:HARMonics:VALue?
IM 253710-11E
Page
4-60
4-60
4-60
4-61
4-63
4-63
4-63
4-63
4-63
"
4-63
4-64
4-64
4-64
4-64
4-64
4-64
4-64
4-64
4-65
4-65
4-65
4-65
4-65
4-69
4-69
4-69
4-69
4-69
4-70
4-70
4-70
4-71
4-71
4-71

Advertisement

Table of Contents
loading

Table of Contents