:CHANnel<x>:SPEed:TYPE
Function
Sets the signal type of the revolution sensor
signal input channel or queries the current
setting.
Syntax
:CHANnel<x>:SPEed:TYPE {ANALog|PULSe}
:CHANnel<x>:SPEed:TYPE?
<x> = 7 (fixed)
Example
:CHANNEL7:SPEED:TYPE ANALOG
:CHANNEL7:SPEED:TYPE?→:CHANNEL7:SPEED:
TYPE ANALOG
Description
• If the 253771 motor module is not installed,
an error will occur.
• The "
:INPut:MOTor:SPEed:TYPE
can be used to make the same settings and
inquiries.
:CHANnel<x>:TORQue?
Function
Queries all settings related to the torque meter
signal input channel.
Syntax
:CHANnel<x>:TORQue?
<x> = 8 (fixed)
Example
:CHANNEL8:TORQUE?→:CHANNEL8:TORQUE:
RANGE 50.0E+00
Description
If the 253771 motor module is not installed, an
error will occur.
:CHANnel<x>:TORQue:RANGe
Function
Sets the input range of the torque meter signal
input channel or queries the current setting.
Syntax
:CHANnel<x>:TORQue:RANGe {<voltage>|
AUTO}
:CHANnel<x>:TORQue:RANGe?
<x> = 8 (fixed)
<voltage> = 1, 2, 5, 10, 20, and 50(V)
AUTO
= Auto range
Example
:CHANNEL8:TORQUE:RANGE 50V
:CHANNEL8:TORQUE:RANGE?→:CHANNEL8:
TORQUE:RANGE 50.0E+00
Description
• If the 253771 motor module is not installed,
an error will occur.
• The "
:INPut:MOTor:TORQue:RANGe
command can be used to make the same
settings and inquiries.
:CHANnel<x>:TYPE?
Function
Queries the input type of each channel.
Syntax
:CHANnel<x>:TYPE?
<x> = 1 to 8
Example
:CHANNEL1:TYPE?→VOLTAGE
Description
The following responses are possible.
VOLTage = voltage input
CURRent = current input
IM 253710-11E
:CHANnel<x>:VOLTage?
Function
Syntax
Example
:CHANnel<x>:VOLTage:RANGe
Function
Syntax
" command
Example
Description
:CHANnel<x>:VZoom
Function
Syntax
Example
"
4.4 CHANnel Group
Queries all settings related to the voltage input
channel.
:CHANnel<x>:VOLTage?
<x> = 1 to 8
:CHANNEL1:VOLTAGE?→:CHANNEL1:VOLTAGE:
RANGE 2.00E+03
Sets the voltage range of the voltage input
channel or queries the current setting.
:CHANnel<x>:VOLTage:RANGe {<voltage>|
AUTO}
:CHANnel<x>:VOLTage:RANGe?
<x> = 1 to 8
<voltage> = 30,60,120,200,300,600,1200,
2000(V)
AUTO
= AUTO RANGE
:CHANNEL1:VOLTAGE:RANGE 2000V
:CHANNEL1:VOLTAGE:RANGE?→:
CHANNEL1:VOLTAGE:RANGE 2.00E+03
The "
:INPut:POWer:VOLTage:RANGe:
ELEMent<x>
(where <x> is the element
number)" command can be used to make the
same settings and inquiries.
Sets the vertical zoom factor or queries the
current setting.
:CHANnel<x>:VZoom {<NRf>}
:CHANnel<x>:VZoom?
<x> = 1 to 8
<NRf> = 0.1 to 100 (See the PZ4000
User's Manual)
:CHANNEL1:VZOOM 1
:CHANNEL1:VZOOM?→:CHANNEL1:VZOOM 1.00