Programming
5.3.10 9-** Profibus
Par.
Parameter description
No. #
9-00
Setpoint
9-07
Actual Value
9-15
PCD Write Configuration
9-16
PCD Read Configuration
9-18
Node Address
9-22
Telegram Selection
9-23
Parameters for Signals
9-27
Parameter Edit
9-28
Process Control
9-44
Fault Message Counter
9-45
Fault Code
9-47
Fault Number
9-52
Fault Situation Counter
9-53
Profibus Warning Word
9-63
Actual Baud Rate
9-64
Device Identification
9-65
Profile Number
9-67
Control Word 1
9-68
Status Word 1
9-71
Profibus Save Data Values
9-72
ProfibusDriveReset
9-75
DO Identification
9-80
Defined Parameters (1)
9-81
Defined Parameters (2)
9-82
Defined Parameters (3)
9-83
Defined Parameters (4)
9-84
Defined Parameters (5)
9-90
Changed Parameters (1)
9-91
Changed Parameters (2)
9-92
Changed Parameters (3)
9-93
Changed parameters (4)
9-94
Changed parameters (5)
9-99
Profibus Revision Counter
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
®
VLT
Decentral Drive FCD 302 Operating Instructions
Default value
0 N/A
0 N/A
App.Dependent
App.Dependent
126 N/A
[100] None
0
[1] Enabled
[1] Enable cyclic master
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
[255] No baudrate found
0 N/A
0 N/A
0 N/A
0 N/A
[0] Off
[0] No action
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
®
MG04F302 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
FALSE
1 set-up
TRUE
2 set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
Type
0
Uint16
0
Uint16
-
Uint16
-
Uint16
0
Uint8
-
Uint8
5
5
-
Uint16
-
Uint16
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
V2
-
Uint8
0
Uint16
OctStr[
0
2]
0
V2
0
V2
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint16
53

Advertisement

Table of Contents
loading