Programming
5.3.2 1-** Load/Motor
Par.
Parameter description
No. #
1-0* General Settings
1-00
Configuration Mode
1-01
Motor Control Principle
1-02
Flux Motor Feedback Source
1-03
Torque Characteristics
1-04
Overload Mode
5
5
1-05
Local Mode Configuration
1-06
Clockwise Direction
1-1* Motor Selection
1-10
Motor Construction
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-29
Automatic Motor Adaptation (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-33
Stator Leakage Reactance (X1)
1-34
Rotor Leakage Reactance (X2)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-37
d-axis Inductance (Ld)
1-39
Motor Poles
1-40
Back EMF at 1000 RPM
1-41
Motor Angle Offset
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-51
Min Speed Normal Magnetising [RPM]
1-52
Min Speed Normal Magnetising [Hz]
1-53
Model Shift Frequency
1-54
Voltage reduction in fieldweakening
1-55
U/f Characteristic - U
1-56
U/f Characteristic - F
1-58
Flystart Test Pulses Current
1-59
Flystart Test Pulses Frequency
42
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
®
VLT
Decentral Drive FCD 302 Operating Instructions
Default value
null
null
[1] 24 V encoder
[0] Constant torque
[0] High torque
[2] As mode par 1-00
[0] Normal
[0] Asynchron
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
[0] Off
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
App.Dependent
0 N/A
100%
App.Dependent
App.Dependent
App.Dependent
0 V
App.Dependent
App.Dependent
30%
200%
®
MG04F302 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
1
Uint32
-2
Uint32
0
Uint16
0
Uint16
-2
Uint32
67
Uint16
-1
Uint32
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
-4
Int32
0
Uint8
0
Uint16
0
Int16
0
Uint16
67
Uint16
-1
Uint16
-1
Uint16
0
Uint8
-1
Uint16
-1
Uint16
0
Uint16
0
Uint16