Programming
1-23 Motor Frequency
Range:
Size
[20 -
related
1000
*
Hz]
5
5
1-24 Motor Current
Range:
Size
related
10000.00 A]
*
NOTE
This parameter cannot be changed while the motor is
running.
1-25 Motor Nominal Speed
Range:
Size related
*
RPM]
NOTE
This parameter cannot be changed while the motor is
running.
5-12 Terminal 27 Digital Input
Option: Function:
Select the function from the available digital input
range.
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC-brake inverse
Stop inverse
Start
Latched start
Reversing
38
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Function:
Min - Max motor frequency: 20-1000 Hz.
Select the motor frequency value from the
motor nameplate data. If a value different
from 50 Hz or 60 Hz is selected, it is
necessary to adapt the load independent
settings in 1-50 Motor Magnetisation at Zero
Speed to 1-53 Model Shift Frequency. For 87
Hz operation with 230/400 V motors, set the
nameplate data for 230 V/50 Hz. Adapt
4-13 Motor Speed High Limit [RPM] and
3-03 Maximum Reference to the 87 Hz
application.
Function:
[0.10 -
Enter the nominal motor current
value from the motor nameplate
data. This data is used for
calculating motor torque, motor
thermal protection etc.
Function:
[100 - 60000
Enter the nominal motor speed
value from the motor nameplate
data. This data is used for
calculating automatic motor
compensations.
MG04F302 - VLT
®
VLT
Decentral Drive FCD 302 Operating Instructions
5-12 Terminal 27 Digital Input
Option: Function:
1-29 Automatic Motor Adaptation (AMA)
Option:
[0]
OFF
*
[0]
[1]
Enable
[1]
complete
AMA
[2]
[3]
[2]
Enable
[4]
reduced
[5]
AMA
[6]
[8]
[9]
[10]
®
is a registered Danfoss trademark
Start reversing
Enable start forward
Enable start reverse
Jog
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Speed down
Set-up select bit 0
Set-up select bit 1
Catch up
Slow down
Pulse input
Ramp bit 0
Ramp bit 1
Mains failure inverse
DigiPot Increase
DigiPot Decrease
DigiPot Clear
Reset Counter A
Reset Counter B
Function:
The AMA function optimizes dynamic motor
performance by automatically optimizing the
advanced motor parameters (1-30 Stator
Resistance (Rs) to 1-35 Main Reactance (Xh)) at
motor standstill.
Activate the AMA function by pressing [Hand
on] after selecting [1] or [2]. See also
3.4 Automatic Motor Adaptation. After a
normal sequence, the display will read: "Press
[OK] to finish AMA". After pressing [OK] the
frequency converter is ready for operation.
This parameter cannot be adjusted while the
motor is running.
Performs AMA of the stator resistance R
rotor resistance R
, the stator leakage
r
reactance X
, the rotor leakage reactance X
1
and the main reactance X
Performs a reduced AMA of the stator
resistance R
in the system only. Select this
s
option if an LC filter is used between the
frequency converter and the motor.
[11]
[12]
[13]
[14]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[28]
[29]
[32]
[34]
[35]
[36]
[55]
[56]
[57]
[62]
[65]
, the
S
2
.
h
Need help?
Do you have a question about the VLT FCD 302 and is the answer not in the manual?