REAR OF SYSTEM

The computer and the UPS are accessible from the back of the system.
Power In
Disconnect Switch
ONBOARD COMPUTER
The onboard computer is the central control unit for the Fortus 900mc. This computer also runs the touchscreen
software that provides for the system's user interface.
UPS
The UPS unit is a battery standby system that supplies power (AC voltage) to the computer, oven lights, and
head cooling fan in the event of a loss of AC power. It does not power the entire system. You can access the
UPS from the back of the system. In the event of an overcurrent condition, the UPS is protected by a
combination on/off switch and circuit breaker located directly above the main breaker.
It shuts itself off if power is not restored to the system.
If power is lost to the system you may need to manually power the unit back up. However, this
should not be necessary unless the UPS has been manually turned off. To regain power, hold
the "On" button on the front of the UPS unit until a beep is heard and/or LED lights appear.
The LED display shows status of the UPS.
On battery
Indicator
(Yellow)
Onboard Computer
Alarm Indicator
(Red)
Power On
Indicator
(Green)
UPS
On/Off
Button
Up
Down
9
Escape
Enter