Technical data

Ratings

Inverter unit type
P
brcont
ACS880-104-...
U
= 400 V
N
004A8-3
006A0-3
008A0-3
0011A-3
0014A-3
0018A-3
0025A-3
11.4
0035A-3
11.4
0044A-3
17.5
0050A-3
17.5
0061A-3
17.5
0078A-3
17.5
0094A-3
17.5
0100A-3
17.5
U
= 500 V
N
003A6-5
004A8-5
006A0-5
008A0-5
0011A-5
0014A-5
0018A-5
0025A-5
11.4
0030A-5
11.4
0035A-5
11.4
0050A-5
17.5
0061A-5
17.5
0078A-5
17.5
0094A-5
17.5
Definitions
P
Maximum continuous braking power. The braking is considered continuous if the braking time
brcont
exceeds 30 seconds.
P
Maximum braking power of the inverter module and its internal brake chopper. The inverter and
brmax
chopper will withstand this braking power for 1 second within every 10 seconds.
Note: The listed resistors will withstand this braking power for 1 second within every 120
seconds.
R
Minimum allowed resistance of the brake resistor.
min
R
Resistance of the listed resistor.
P
Continuous power (heat) dissipation of the listed resistor when placed correctly.
n
E
Short energy pulse that the listed resistor will withstand every 400 seconds.
R
The ratings apply at an ambient temperature of 40 °C (104 °F).
The listed brake resistors are protected to IP20. Refer to page
sizes and tightening torques for the resistors.
Resistor braking using frame R1i...R4i inverter modules 331
Output ratings
P
R
brmax
min
kW
kW
ohm
1.8
3.3
120
1.9
3.3
120
1.9
3.3
120
2.8
50
80
5.7
10.0
40
5.7
10.0
40
20.0
20
20.0
20
30.8
13
30.8
13
30.8
13
30.8
13
30.8
13
30.8
13
1.3
5.5
120
1.8
5.5
120
1.9
5.5
120
1.9
5.5
120
2.8
7.9
80
5.7
14.6
40
5.7
14.6
40
30.7
20
30.7
20
30.7
20
43.9
13
43.9
13
43.9
13
43.9
13
Brake resistor example
Type
JBR-01 (Danotherm
CAR 155 D T 414 120R)
JBR-03 (Danotherm
CAR 200 D T 415 80R)
JBR-04 (Danotherm
CBR-V 210 D T 415 40R)
JBR-05 (Danotherm
CBR-V 330 D T 415 20R)
JBR-06 (Danotherm
CBR-V 460 D HT 415 13R)
JBR-01 (Danotherm
CAR 155 D T 414 120R)
JBR-03 (Danotherm
CAR 200 D T 415 80R)
JBR-04 (Danotherm
CBR-V 210 D T 415 40R)
JBR-05 (Danotherm
CBR-V 330 D T 415 20R)
JBR-06 (Danotherm
CBR-V 460 D HT 415 13R)
332
P
E
R
n
R
ohm
W
kJ
120
105
22
80
135
40
40
360
73
20
570
77
13
790
132
120
105
22
80
135
40
40
360
73
20
570
77
13
790
132
for dimensions, wire