6 Operating through a database

TM
6.1 OtoAccess
It is possible to operate the AA222 through Diagnostic suite to a database. This makes it possible to save the
obtained data directly to either one client in Otoaccess
6.1.1

Upload clients to the device and save the measurements to the clients

This way of transferring data is designed to transfer multiple clients simultaneously prior to starting testing. Once
all the measurements are completed, this data can then also be transferred simultaneously.
1)
Open Diagnostic suite through Otoaccess
information to.
2)
Go to the Sync tab and press Client upload. Select all the clients you wish to transfer to the device by
highlighting them and pressing Add. The clients will now appear in the list on the right and will be added to
the device.
3)
Disconnect the device from Diagnostic suite and start the session's measurements.
4)
Once the session is completed, press Save session and select the client you would like to save the
information to. Then press Save on the device.
5)
At the end of the day connect the device to Diagnostic suite through Otoaccess
When the device is connected to the suite in the SYNC tab, it will state 'Online and PC controlled mode' on
the AA222 screen. In the SYNC tab the clients will appear in a list (if not press Refresh).The data obtained
on the device will automatically be transferred to the client in the Otoaccess
'Already in database' (see example below).
6)
Press Save or Save & Exit in the suite to save the data.
7)
The data can then be used for further interpretation or review in Diagnostic suite through Otoaccess
6.1.2

Download the client information to one patient

1)
Open Diagnostic suite through Otoaccess
2)
Obtain the measurement on the device with the device connected to the Diagnostic suite including
audiometry and impedance.
3)
Once completed press Save session on the device. The measurement will be transferred to Diagnostic
suite and appear in the Audiometry and Impedance tab.
4)
From here it is also possible to print to PDF or a printer, so that the results can be shared externally.
Please refer to the section regarding the Print Wizard for further information.
5)
Press Save or Save & Exit in the suite to save the data to the selected client in Otoaccess

6.2 NOAH

It is possible to operate the AA222 through Diagnostic suite to a database. This makes it possible to save the
obtained data directly to a client created in NOAH.
6.2.1

Download the client information to a patient using NOAH

1) Open Diagnostic suite through NOAH with your client selected.
2) Obtain the measurement on the device with the device connected to the Diagnostic suite including
audiometry and impedance.
3) Once completed press Save session on the device. The measurement will be transferred to Diagnostic
suite and appear in the Audiometry and Impedance tab.
4) Press Save or Save & Exit in the suite to save the data in NOAH.
5) The data can then be used for further interpretation and fitting of hearing aids through NOAH.
TM
or multiple clients in Otoaccess
TM
with a client selected, that is not used for storing any
TM
with your client selected.
Page 45
TM
.
TM
and go to the SYNC tab.
TM
database, and state
TM
TM
.
.

Advertisement

Table of Contents
loading

Table of Contents