Alarm Procedures
The Fail to Switch to Protection Path condition occurs when the circuit does not switch from the working
path to the protect path on a path protection configration. Common causes of the FAILTOSW-HO
condition include a missing or defective protect port, a lockout set on one of the SNCP nodes, or
path-level alarms that would cause a SNCP switch to fail including the
page
condition on page
The
on page
Clear the FAILTOSW-HO Condition in a Path Protection Configuration
Step 1
Look up and clear the higher priority alarm. If the
alarm on page
"HP-DEG" condition on page
page
occurring on the reporting port, complete the applicable alarm clearing procedure.
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.63 FAN
The Fan Failure alarm indicates a problem with the internal fan of the ONS 15310-MA SDH. When the
fan is not fully functional, the temperature of the node can rise above its normal operating range.
The Fan Failure alarm is also reported against the fan unit located inside the ONS 15310-MA if only one
power source is connected to the chassis, or if any fuse blows.
This alarm is not user-serviceable. If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC to report a
Service-Affecting (SA) problem (1-800-553-2447).
2.7.64 FANDEGRADE
The Partial Fan Failure Speed Control Degradation alarm occurs if fan speed for one of the fans in the
ONS 15310-MA SDH shelf falls under 500 RPM when read by a tachometry counter.
For an ONS 15310-MA SDH, refer to the fan tray replacement procedure located in the
Cisco ONS15310-MA SDH Procedure Guide.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
2-58
SDH Logical Objects: VCMON-HP, VCMON-LP
2-20, the
"AU-LOP" alarm on page
2-126, and the
"LOF (STM)" alarm on page
2-123, or the
"MS-EXC" condition on page 2-126
2-91, the
"HP-UNEQ" alarm on page
2-124, the
2-98, the
"MS-DEG" condition on page
Default Severity: Critical (CR), Service-Affecting (SA)
SDH Logical Object: FAN
Default Severity: Major (MJ), Non-Service-Affecting (NSA)
SDH Logical Object: FAN
2-91, the
"HP-DEG" condition on page
"HP-UNEQ" alarm on page
2-88, the
"LOS (STM)" alarm on page
can also occur on the failed path.
"AU-AIS" condition on page
2-141, the
"LOF (STM)" alarm on page
2-123, or the
"MS-EXC" condition on page 2-126
Chapter 2
Alarm Troubleshooting
"AU-AIS" condition on
2-124, the
2-141.
2-98, the
"MS-DEG" condition
2-20, the
"HP-EXC" condition on page
2-88, the
"LOS (STM)" alarm on
"HP-EXC"
"AU-LOP"
2-126, the
are also
78-18663-01