Chapter 2
Alarm Troubleshooting
2.7.26 AUTOSW-UNEQ-SNCP (VCMON-LP)
The automatic path protection switch caused by an unequipped condition (VCMON-LP) indicates that
the
the SNCP is configured for revertive switching, it reverts to the working path after the fault clears.
Note
This condition is only reported if the path protection is set up for revertive switching.
Clear the AUTOSW-UNEQ-SNCP (VCMON-LP) Alarm
Complete the
Step 1
If the alarm does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447) in order to report a Service-Affecting (SA) problem.
2.7.27 BAT-FAIL
The Battery Fail alarm occurs when the power supply is not detected. This could be because the supply
is removed or is not operational. The alarm does not distinguish between the individual power supplies,
so onsite information about the conditions is necessary for troubleshooting.
Clear the BAT-FAIL Alarm
Step 1
At the site, determine which battery is not present or operational.
Step 2
Remove the power cable from the faulty supply. The "Install the Cisco ONS 15310-MA SDH" chapter
in the Cisco ONS15310-MA SDH Procedure Guide contains instructions for installing DC (ONS
15310-MA SDH) power supply cables. To remove the cable, reverse the appropriate procedure.
Always use the supplied electrostatic discharge wristband when working with a powered
Caution
ONS 15310-MA SDH.
If the alarm does not clear, log into the Technical Support Website at
Step 3
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447) in order to report a Service-Affecting (SA) problem.
78-18663-01
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: VCMON-LP
"LP-UNEQ" alarm on page 2-142
"Clear the LP-UNEQ Alarm" procedure on page
Default Severity: Major (MJ), Service-Affecting (SA)
SDH Logical Object: PWR
alarm caused automatic SNCP protection switching to occur. If
2-143.
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
Alarm Procedures
2-31