Download Print this page

Cisco ONS 15310-MA Troubleshooting Manual page 49

Hide thumbs Also See for ONS 15310-MA:

Advertisement

Chapter 2
Alarm Troubleshooting
The Extreme Low Voltage Battery alarm occurs in a –48 VDC environment when a battery lead input
voltage falls below the extreme low power threshold. This threshold has a preset value of –40 VDC and
is not user-provisionable. The alarm remains raised until the voltage remains over the threshold for
120 seconds.
Clear the ELWBATVG Alarm
The problem is external to the ONS 15310-MA SDH. Troubleshoot the power source supplying the
Step 1
battery leads.
If the alarm does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447) in order to report a Service-Affecting (SA) problem.
2.7.52 ENCAP-MISMATCH-P
The Encapsulation C2 Byte Mismatch Path alarm applies to the ML-100T-8 Ethernet card. It occurs
when the first three following conditions are met and one of the last two is false:
(This is in contrast to the
ENCAP-MISMATCH-P alarm to be raised, there is a mismatch between the received and expected C2
byte, with either the expected byte or received byte value being 0x01.
For example, an ENCAP-MISMATCH-P alarm is raised if a circuit created between two ML-100T-8
cards has generic framing procedure (GFP) framing provisioned on one end and high-level data link
control (HDLC) framing with LEX encapsulation provisioned on the other. The GFP-framing card
transmits and expects a C2 byte of 0x1B, while the HDLC-framing card transmits and expects a C2 byte
of 0x01.
A mismatch between the transmit and receive ports on any of the following parameters can cause the
alarm:
This alarm is demoted by LP-PLM or HP-PLM.
78-18663-01
Default Severity: Critical (CR), Service-Affecting (SA)
SDH Logical Object: VCTRM-LP, VCTRM-HP
The received C2 byte is not 0x00 (unequipped).
The received C2 byte is not a PDI value.
The received C2 does not match the expected C2.
The expected C2 byte is not 0x01 (equipped unspecified).
The received C2 byte is not 0x01 (equipped unspecified).
"LP-PLM" alarm on page
Mode (HDLC, GFP-F)
Encapsulation (LEX, HDLC, PPP)
CRC size (16 or 32)
Scrambling state (on or off)
2-113, which must meet all five criteria.) For an
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
Alarm Procedures
2-49

Advertisement

loading