Alarm Procedures
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.24 AUTOSW-SFBER-SNCP
The Automatic USPR Switch Caused by Signal Fail Bit Error Rate (SFBER) condition indicates that a
"HP-EXC" condition on page 2-126
protection is configured for revertive switching, the path protection reverts to the working path when the
HP-EXC is resolved.
This condition is only reported if the path protection is set up for revertive switching.
Note
Clear the AUTOSW-SFBER-SNCP Condition
Step 1
Complete the
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.25 AUTOSW-UNEQ-SNCP (VCMON-HP)
The Automatic Path Protection Switch Caused by Unequipped condition indicates that an UNEQ alarm
caused automatic SNCP protection switching to occur (see the
If the SNCP is configured for revertive switching, it reverts to the working path after the fault clears.
This condition is only reported if the path protection is set up for revertive switching.
Note
Clear the AUTOSW-UNEQ-SNCP (VCMON-HP) Condition
Complete the
Step 1
If the condition does not clear, log into the Technical Support Website at
Step 2
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
2-30
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: VCMON-HP, VCMON-LP
"Clear the HP-EXC Condition" procedure on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: VCMON-HP
"Clear the HP-UNEQ Alarm" procedure on page
caused automatic SNCP protection switching to occur. If the path
Chapter 2
Alarm Troubleshooting
2-127.
"HP-UNEQ" condition on page
2-141.
2-141).