List of Error Codes for Micro800 controllers
Error Code Fault Type Description
0xF010
Recoverable The user program contains a function/function
block that is not supported by the Micro800
controller.
0xF014
Recoverable A memory module memory error occurred.
0xF015
Non-
An unexpected software error occurred.
recoverable
0xF016
Non-
An unexpected hardware error occurred.
recoverable
0xF017
Non-
An unexpected software error occurred due to
recoverable
unexpected hardware interrupt.
If the system variable
_SYSVA_USER_DATA_LOST is set, the controller
is able to recover the user program but the user
data is cleared. If not, the Micro800 controller
program is cleared.
0xF018
Non-
An unexpected software error occurred due to SPI
recoverable
communication failure.
If the system variable
_SYSVA_USER_DATA_LOST is set, the controller
is able to recover the user program but the user
data is cleared. If not, the Micro800 controller
program is cleared.
0xF019
Non-
An unexpected software error occurred due to
recoverable
memory or other controller resource issue.
0xF01A
Recoverable The controller was unexpectedly reset during Run
Mode Change (RMC) due to a noisy environment
or an internal hardware failure.
If the system variable
_SYSVA_USER_DATA_LOST is set, the controller
is able to recover the user program but the user
data is cleared. If not, the Micro800 controller
program is cleared.
0xF020
Recoverable The base hardware faulted or is incompatible
with the Micro800 controller's firmware revision.
0xF021
Recoverable The I/O configuration in the user program is
invalid or does not exist in the Micro800
controller.
0xF022
Recoverable The user program in the memory module is
incompatible with the Micro800 controller's
firmware revision.
Rockwell Automation Publication 2080-UM005E-EN-E - March 2018
Recommended Action
Perform one of the following:
• See
Corrective Actions for Recoverable Faults on page
• Contact your local Rockwell Automation technical support
representative.
• See
Corrective Actions for Recoverable Faults on page
• Reprogram the memory module. If the error persists, replace the
memory module.
Perform one of the following:
• See
Corrective Actions for Non-recoverable Faults on page
• Refer to
Wiring Requirements and Recommendation on page
Perform one of the following:
• See
Corrective Actions for Non-recoverable Faults on page
• Refer to
Wiring Requirements and Recommendation on page
Perform one of the following:
• See
Corrective Actions for Non-recoverable Faults on page
• Refer to
Wiring Requirements and Recommendation on page
Perform one of the following:
• See
Corrective Actions for Non-recoverable Faults on page
• Refer to
Wiring Requirements and Recommendation on page
See
Corrective Actions for Non-recoverable Faults on page
See
Corrective Actions for Recoverable Faults on page
See
Corrective Actions for Recoverable Faults on page
See
Corrective Actions for Recoverable Faults on page
Perform one of the following:
• See
Corrective Actions for Recoverable Faults on page
• Replace the memory module.
Appendix B
Troubleshooting
149.
149.
149.
37.
149.
37.
149.
37.
149.
37.
149.
149.
149.
149.
149.