Rockwell Automation Publication 2080-UM005E-EN-E - March 2018
Analog input to thermistors
Thermistor 3
Thermistor 2
Thermistor 1
Thermistor 0
Note: Terminal block to wire
commons is not included in
Micro800 package.
The "+DC10" terminal supplies 10V DC power source to the Thermistor inputs (I-00 to I-03).
Calculate for Thermistor Resistance
While connecting Analog input to thermistor as shown in previous diagram,
calculate input voltage using the following equation:
R
i
V
=
i
R
+ R
i
t
To calculate for thermistor resistance, use the following equation:
R
V
- V
R
i
ref
i
i
R
=
t
V
i
Where:
V
= Voltage input (±5% without calibration; ±2% with calibration)
i
R
= Resistance input (14.14 KΩ ±2%)
i
R
= Thermistor resistance (10 KΩ Thermistor is recommended)
t
V
= 10V ±0.5V
ref
Micro820 controllers support 10 KΩ type thermistors.