Calibrating Wire Feed Speed - Kemppi HiArc M 400R Operating Manual

Table of Contents

Advertisement

3.8

Calibrating wire feed speed

To ensure that the pre-sets and meter displays work as planned, you must calibrate the wire
feed speed of your Hiarc power source and F 10 wire feeder welding equipment.
Calibration
1.
Start the calibration by pressing Crater Fill button for 3 seconds.
2.
Press Gas Test button to select either HiArc F 10 or HiArc F 30 wire feeder.
3.
Cut the filler wire at the contact tip.
4.
Press Wire Inch button at the wire feeder.
• Wire feed starts and continues for 12 seconds
5.
When wire feed stops, cut the wire at the contact tip and measure the length of the fed
wire in mm.
© Kemppi Oy / 1308
EN
13