3.5

selecting shielding gas

Press the shielding gas selection button to set the shielding gas type to either CO₂ or mixed
gas according to the gas you are using.
Select CO₂ if you are using carbon dioxide. Select Ar + CO₂ (MAG) if you are using mixed gas.
HiArc M has a factory set pre-gas time of 0.2 s and a Post-gas time of between 2 – 4 s,
NOTE!
depending on the welding power settings.
3.6

gas test

To test the shielding gas flow, press the gas test button once. The shielding gas starts to flow
and stops automatically after 20 seconds.
To interrupt the gas test, press the button again.
3.7

trigger logic and Crater Fill function

The HiArc M 400R power source is equipped with a crater fill function, which makes your
welding more efficient and helps you avoid welding defects at the end of the weld sequence.
With this function you can use an additional crater fill current level, which can be lower or
higher than your normal welding current level.
2t mode
MIG welding with 2T mode of the gun trigger.
• Push the trigger – welding starts after preset pre-gas time.
• Release the trigger – welding ends. Post-gas flows for preset time.
1.
1.
Pre-gas time
2.
Post-gas time
2t mode and crater fill function
• Push the trigger – welding starts after preset pre-gas time.
• Release the trigger – values drop to preset crater fill level and welding ends after preset
time. Post-gas flows for preset time.
1.
1.
Pre-gas time
2.
Crater fill time
3.
Post-gas time
© Kemppi Oy / 1308
2.
2.
3.