Calibrating Wire Feed Speed - Kemppi HiArc M 350A Operating Manual

Table of Contents

Advertisement

Using the CV mode
• Turn the CV mode on by pressing Crater fill and 2T/4T buttons simultaneously.
• When the CV mode is on, the voltage is shown on the display with one of the digits
blinking (the active digit).
• You can change the voltage value by pressing Gas select (decrease the active digit) or
2T/4T (increase the active digit) buttons. You can change the active digit by pressing
Crater fill button.
• The machine is now ready for carbon arc gouging.
• Exit CV mode by pressing the welding gun trigger or pressing Crater fill and 2T/4T
buttons simultaneously.
For your safety, the CV mode turns off automatically if you use the
NOTE!
press the welding gun trigger.
3.7

Calibrating wire feed speed

To ensure that the pre-sets and meter displays work as planned, you must calibrate the wire
EN
feed speed of your Hiarc power source and F 10 wire feeder welding equipment.
Calibration
1.
Start the calibration by pressing Crater Fill button for 3 seconds.
2.
Press Gas Test button to select either HiArc F 10 or HiArc F 30 wire feeder.
3.
Cut the filler wire at the contact tip.
4.
Press Wire Inch button at the wire feeder.
• Wire feed starts and continues for 12 seconds
18
HiArc M 350A, M 500A
4
7
3
8
2
9
1
WIRE INCH
5
6
7
4
3
8
2
9
1
10
Wire Inch button
Wire Inch
button or