Calibrating wire feed speed

To ensure that the pre-sets and meter displays work as planned, you must calibrate the wire
feed speed of your Hiarc power source and F 10 wire feeder welding equipment.
Calibration
1.
Start the calibration by pressing Crater Fill button for 3 seconds.
2.
Press Gas Test button to select either HiArc F 10 or HiArc F 30 wire feeder.
EN
3.
Cut the filler wire at the contact tip.
4.
Press WIRE INCH button at the wire feeder.
• Wire feed starts and continues for 12 seconds
5.
When wire feed stops, cut the wire at the contact tip and measure the length of the fed
wire in mm.
18