Table 26. TapeAlert flags supported by the library (continued)
Flag
Flag Name
Number
06
Library
Interface
08
Library
Maintenance
12
Library Stray
Tape
13
Library Pick
Retry
14
Library Place
Retry
16
Library I/O
station
17
Library
Mailslot
18
Library
Magazine
21
Library Offline Library manually
22
Library Drive
Offline
130
Dell PowerVault TL1000 Tape Autoloader: User's Guide
Description
The library
1. Check all cables and cable connections.
identified an
2. Restart the operation.
interface fault.
3. If the problem persists, see "Contacting
Dell technical support" on page 111.
Library preventive
Preventive maintenance of the library is
maintenance
required. Consult the library user's manual for
required.
device-specific preventive maintenance tasks.
A cartridge was left
1. Try unloading the cartridge from the drive
in the drive inside
with the Operator Panel or Web User
the library by a
Interface.
previous hardware
v If the cartridge unloads, move the
fault.
v If the cartridge did not unload from the
2. If the problem persists, see "Contacting
Dell technical support" on page 111.
There is a potential
No action is required.
problem with the
drive ejecting a
cartridge short or
with the library
mechanism picking
a cartridge from a
slot.
There is a potential
No action is required.
problem with the
library mechanism
placing a cartridge
into a slot.
The operation failed
Close the I/O station.
because the library
I/O station is open.
Mechanical problem
There is a mechanical problem with the library
with the I/O
I/O station.
station.
Library magazine
The library cannot operate without the
not present.
magazine.
1. Insert the magazine into the library.
2. Restart the operation.
The library was manually turned offline and is
turned offline.
unavailable for use.
Library turned
The drive inside the library was taken offline.
internal drive
This flag is for information purposes only. No
offline.
action is required.
Action Required
cartridge from the drive to the I/O
station. Remove the cartridge and inspect
for damage. If not damaged, return the
cartridge to the library. Run Library
Verify before normal library operations
resume.
drive, cycle the power supply and try