Table 22. Library error codes (continued)
Code (H)
Description
Commands to the encryption
002B
capable drive over the retry limit.
LDI I/F error.
002C
ACK IU event timeout detected.
LDI I/F error.
002D
Response IU event timeout
detected.
LDI I/F error.
002E
Transfer Ready IU event timeout
detected.
LDI I/F error.
002F
Undefined error detected.
A drive media error detected
0040
upon insertion.
A hardware error detected upon
0041
media insertion
A drive load timeout error
0042
detected upon insertion.
0048
Incompatible medium installed.
Panel Indication
1. Reseat all cables. See "Reseating cables" on
page 108.
2. Cycle the power supply and try again.
v If the problem is corrected, run Library
-
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
Dell technical support" on page 111.
Cycle the power supply and try again.
-
v If the problem is corrected, run Library Verify
before normal library operations resume.
v If the problem persists, see "Contacting Dell
technical support" on page 111.
-
-
-
1. Verify that the cartridge is compatible with
the drive in your library. See "Cartridge
compatibility" on page 93.
CHK 0040
2. Verify that the cartridge is not
write-protected. See "Write-Protect switch"
on page 97.
3. If it is a cleaning cartridge, verify that the
cartridge is not expired. See "Cleaning
cartridge" on page 95.
4. Cycle the power supply and try again.
v If the problem is corrected, run Library
CHK 0041
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
Dell technical support" on page 111.
Cycle the power supply and try again.
v If the problem is corrected, run Library Verify
CHK 0042
before normal library operations resume.
v If the problem persists, see "Contacting Dell
technical support" on page 111.
Verify that the cartridge is compatible with the
drive installed in the library. See "Cartridge
compatibility" on page 93.
CHK 0048
v If the problem is corrected, run Library Verify
before normal library operations resume.
v If the problem persists, see "Contacting Dell
technical support" on page 111.
Action Required