Table 22. Library error codes (continued)
Code (H)
Description
An error detected during bar code
reader firmware check. Suspect
00DD
the bar code reader cable
connection.
Write operation not finished
00E0
within 1 ms when writing data to
flash memory.
Clear operation not finished
00E1
within 10 seconds when clearing a
sector in flash memory.
Error detected in tape library
00E2
configuration stored in flash
memory.
Checksum error detected in flash
00E3
memory.
Sensor error #1.
Accessor encoder sensor B error
00F0
detected during blink check.
Suspect the accessor encoder
sensor B.
Panel Indication
1. Initiate an inventory. See "Conducting a
library inventory" on page 56 (Operator
Panel) or "Conducting a library inventory"
on page 71 (Web User Interface).
2. Cycle the power supply and try again.
CHK 00DD
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
Dell technical support" on page 111.
Cycle the power supply and try again.
CHK 00E0
v If the problem is corrected, run Library Verify
before normal library operations resume.
v If the problem persists, see "Contacting Dell
CHK 00E1
technical support" on page 111.
CHK 00E2
CHK 00E3
CHK 00F0
Action Required
Appendix A. Error codes
123

Advertisement