Fault code No. P0351
Fault code No.
Item
Fail-safe system
Diagnostic code No.
Actuation
Procedure
Probable cause of malfunc-
Item
tion and check
1
Connection of cylinder-#1 igni-
tion coil coupler.
Check the locking condition of
the coupler.
Disconnect the coupler and
check the pins (bent or broken
terminals and locking condition
of the pins).
2
Connection of ECU coupler.
Check the locking condition of
the coupler.
Disconnect the coupler and
check the pins (bent or broken
terminals and locking condition
of the pins).
3
Wire harness continuity.
4
Installed condition of cylinder-#1
ignition coil.
P0351
Cylinder-#1 ignition coil: open or short circuit detected in the pri-
mary lead of the cylinder-#1 ignition coil.
Able to start engine (depending on the number of faulty cylinders)
Able to drive vehicle (depending on the number of faulty cylinders)
30
Actuates the cylinder-#1 ignition coil five times at one-second intervals.
The "check" indicator on the Yamaha diagnostic tool screen comes on
each time the ignition coil is actuated.
Check that a spark is generated five times.
• Connect an ignition checker.
Maintenance job
Improperly connected  Con-
nect the coupler securely or
replace the wire harness.
Improperly connected  Con-
nect the coupler securely or
replace the wire harness.
Open or short circuit  Replace
the wire harness.
Between cylinder-#1 ignition coil
coupler and ECU coupler.
orange–orange
Between cylinder-#1 ignition coil
coupler and handlebar switch
coupler (right).
red/black–red/black
Check for looseness or pinch-
ing.
Improperly installed ignition coil
 Reinstall or replace the igni-
tion coil.
8-61
FUEL INJECTION SYSTEM
Confirmation of service com-
Start the engine and let it idle for
approximately 5 seconds.
Check the condition of the fault
code using the malfunction
mode of the Yamaha diagnostic
tool.
Condition is "Recovered"  Go
to item 7 and finish the service.
Condition is "Detected"  Go to
item 2.
Start the engine and let it idle for
approximately 5 seconds.
Check the condition of the fault
code using the malfunction
mode of the Yamaha diagnostic
tool.
Condition is "Recovered"  Go
to item 7 and finish the service.
Condition is "Detected"  Go to
item 3.
Start the engine and let it idle for
approximately 5 seconds.
Check the condition of the fault
code using the malfunction
mode of the Yamaha diagnostic
tool.
Condition is "Recovered"  Go
to item 7 and finish the service.
Condition is "Detected"  Go to
item 4.
Start the engine and let it idle for
approximately 5 seconds.
Check the condition of the fault
code using the malfunction
mode of the Yamaha diagnostic
tool.
Condition is "Recovered"  Go
to item 7 and finish the service.
Condition is "Detected"  Go to
item 5.
pletion