Auxiliary Equipment Inactive - Hayward ProLogic Troubleshooting Manual

Hide thumbs Also See for ProLogic:
Table of Contents

Advertisement

6. Auxiliary Equipment Inactive

The ProLogic should only attempt to turn on wired equipment if the LED next to the
specific auxiliary or valve is illuminated.
Inspect relay LED
Service mode
Step 6A
Step 6B
The ProLogic will only attempt to engage a relay if the
Activate service mode & press the relay button. IF the
specific Auxiliary LED is illuminated on the display.
LED illuminates, a control related feature is overriding
Press the Auxiliary button that corresponds with the
the relay (example: interlock...etc.), go to step 6C. IF
relay in question. IF the relay LED fails to turn ON,
LED does not turn ON contact a pool professional by
proceed to step 6B. IF ON, jump ahead to step 6C for
visiting:
https://www.hayward-
more information.