4. Freeze Protection Active: In Error

Freeze Protection is a safety feature built into ProLogic systems to protect all freeze
enabled equipment from dangerously low temperatures.
Verify ambient temperature
Locate & inspect air sensor
Step 4A
Step 4B
Freeze Protection will run between a range of 33ºF -
Navigate through the 'Default Menu', press the (>) until
42ºF. IF the air temperature is within this range, this
the air temperature readout appears. IF the sensor is
operation is justified and interruption is not
not reading accurately, try moving it to see if the
recommended. IF ambient temperatures are well above
reading improves. IF the reading still does not improve,
this range, go to step 4B.
go to step 4C.