How To: Clean the TurboCell (cont.)
The TurboCell draws amperage when power is applied, during chlorination. The
amperage draw will be impaired when calcium and other debris exist within the cell's
electrolytic grid; this in turn effects the salt reading and chlorination efficiency.
Mix: 4 Parts H
2
Step 3
Mix a solution comprised of 4 parts water to 1 part
Muriatic Acid. Always Add Acid to Water. Once mixed
turn the turbo up vertically either in a bucket or using
the recommended cell cleaning stand.
ALWAYS: STORE MIXED SOLUTIONS IN A SAFE AREA, OUT OF HARMS WAY.
When the solution is depleted, follow the manufacturer's instructions for proper disposal.
14
O / 1 Part Muriatic Acid
1 Part:
Muriatic Acid
4 Parts:
Water
NOTE: ALWAYS ADD ACID TO WATER! NEVER ADD WATER TO ACID.
The cell cleaning solution may be reused a few times.
Carefully Pour Solution into Cell
Step 4
Cleaning Tip:
For best results,
stand the cell
vertically with
cord-side down
Carefully pour the solution into the cell until it reaches
the top. The solution should remain in the cell for 15
minute intervals until the reaction is complete.
Carefully, pour solution back into approved container.