4.1. Power Board Assembly

The HEX RC is factory wired for either 100/200 VAC or 115/230 VAC input voltage.
D A N G E R : Always disconnect the Mains power connection before opening the HEX RC
chassis. Fuses must not be changed with Mains power applied to unit.
MATE:
MATE:
ECK00213
ECK00213
TB3
TB4
1
1
B
S2
A
1
TB2
MATE: ECK01577
B
S1
A
1
TB1
MATE: ECK01577
Table 4-1:
Component Select
Component
100/115 VAC
SW1, SW2
BW4, BW6
BW5
50
1
J1
K1
Figure 4-1:
200/230VAC
B
A
-
-
-
-
Chapter 4
BR2
BR1
Board Assembly
Drawing Number: 690D1645, Rev. -1
Power Board
Bipolar
-
Factory Select
Installed
Maintenance
C2
C1
Unipolar
-
Installed
Factory Select
www.aerotech.com