GE N60 Instruction Manual page 491

Network stability and synchrophasor measurement system ur series
Hide thumbs Also See for N60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 61 of 62)
ADDR
REGISTER NAME
D382
Remote Device 1 SqNum
D384
...Repeated for Remote Device 2
D388
...Repeated for Remote Device 3
D38C
...Repeated for Remote Device 4
D390
...Repeated for Remote Device 5
D394
...Repeated for Remote Device 6
D398
...Repeated for Remote Device 7
D39C
...Repeated for Remote Device 8
D3A0
...Repeated for Remote Device 9
D3A4
...Repeated for Remote Device 10
D3A8
...Repeated for Remote Device 11
D3AC
...Repeated for Remote Device 12
D3B0
...Repeated for Remote Device 13
D3B4
...Repeated for Remote Device 14
D3B8
...Repeated for Remote Device 15
D3BC
...Repeated for Remote Device 16
Phasor Measurement Unit Communication (Read/Write Setting) (4 modules)
D400
PMU 1 Communication Port 1 Type
D401
PMU 1 Communication Port 2 Type
D402
PMU 1 Communication Port 3 Type
D403
PMU 1 Port 1 PHS-x (14 items)
D411
PMU 1 Port 2 PHS-x (14 items)
D41F
PMU 1 Port 3 PHS-x (14 items)
D42D
PMU 1 Communication Port 1 PHS-x Name (14 items)
D49D
PMU 1 Port 2 PHS-x Name (14 items)
D50D
PMU 1 Port 3 PHS-x Name (14 items)
D57D
PMU 1 Port 1 A-CH-x (8 items)
D585
PMU 1 Port 2 A-CH-x (8 items)
D58D
PMU 1 Port 3 A-CH-x (8 items)
D595
PMU 1 Port 1 A-CH-x Name (8 items)
D5D5
PMU 1 Port 2 A-CH-x Name (8 items)
D615
PMU 1 Port 3 A-CH-x Name (8 items)
D655
PMU 1 Port 1 D-CH-x (16 items)
D665
PMU 1 Port 2 D-CH-x (16 items)
D675
PMU 1 Port 3 D-CH-x (16 items)
D685
PMU 1 Port 1 D-CH-x Name (16 items)
D705
PMU 1 Port 2 D-CH-x Name (16 items)
D785
PMU 1 Port 3 D-CH-x Name (16 items)
D805
PMU 1 Port 1 D-CH-x Normal State (16 items)
D815
PMU 1 Port 2 D-CH-x Normal State (16 items)
D825
PMU 1 Port 3 D-CH-x Normal State (16 items)
D835
...Repeated for PMU 2
DC6A
...Repeated for PMU 3
E09F
...Repeated for PMU 4
Phasor Measurement Unit Recording Command (Read/Write Command) (4 modules)
E4D4
PMU 1 Recording Clear Command
E4D5
PMU 1 Recording Force Trigger
E4D6
...Repeated for PMU 2
E4D8
...Repeated for PMU 3
E4DA
...Repeated for PMU 4
Phasor Measurement Unit Recording Ex (Read/Write Setting) (4 modules)
E636
PMU 1 Recording Rate
E637
PMU 1 No of Timed Records
E638
PMU 1 Trigger Mode Ex
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
0 to 4294967295
---
0 to 5
---
0 to 5
---
0 to 5
---
0 to 14
---
0 to 14
---
0 to 14
---
---
---
---
---
---
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
---
---
---
---
---
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
---
---
---
---
---
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 11
---
2 to 128
---
0 to 1
---
B.4 MEMORY MAPPING
FORMAT
DEFAULT
1
F003
0
1
F545
0 (Network)
1
F545
0 (Network)
1
F545
0 (Network)
1
F543
1 (Va)
1
F543
1 (Va)
1
F543
1 (Va)
---
F203
"GE-UR-PMU-PHS 1"
---
F203
"GE-UR-PMU-PHS 1"
---
F203
"GE-UR-PMU-PHS 1"
1
F600
0
1
F600
0
1
F600
0
---
F203
"AnalogChannel 1"
---
F203
"AnalogChannel 1"
---
F203
"AnalogChannel 1"
1
F300
0
1
F300
0
1
F300
0
---
F203
"Dig Channel 1"
---
F203
"Dig Channel 1"
---
F203
"Dig Channel 1"
1
F108
0 (Off)
1
F108
0 (Off)
1
F108
0 (Off)
1
F126
0 (No)
1
F126
0 (No)
1
F544
3 (5/sec.)
1
F001
10
1
F542
0 (Auto Overwrite)
B-69
B

Advertisement

Table of Contents
loading

Table of Contents