B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 22 of 62)
ADDR
REGISTER NAME
User Displays Settings (Read/Write Setting) (16 modules)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 items)
4C19
Reserved (7 items)
B
4C20
...Repeated for User-Definable Display 2
4C40
...Repeated for User-Definable Display 3
4C60
...Repeated for User-Definable Display 4
4C80
...Repeated for User-Definable Display 5
4CA0
...Repeated for User-Definable Display 6
4CC0
...Repeated for User-Definable Display 7
4CE0
...Repeated for User-Definable Display 8
4D00
...Repeated for User-Definable Display 9
4D20
...Repeated for User-Definable Display 10
4D40
...Repeated for User-Definable Display 11
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
4DA0
...Repeated for User-Definable Display 14
4DC0
...Repeated for User-Definable Display 15
4DE0
...Repeated for User-Definable Display 16
Field Unit Raw Data Actuals (Read Only) (8 modules)
4E00
Raw Field Data AC1 Mag
4E02
Raw Field Data AC1 Angle
4E03
Raw Field Data AC2 Mag
4E05
Raw Field Data AC2 Angle
4E06
Raw Field Data AC3 Mag
4E08
Raw Field Data AC3 Angle
4E09
Raw Field Data AC4 Mag
4E0B
Raw Field Data AC4 Angle
4E0C
Raw Field Data AC5 Mag
4E0E
Raw Field Data AC5 Angle
4E0F
Raw Field Data AC6 Mag
4E11
Raw Field Data AC6 Angle
4E12
Raw Field Data AC7 Mag
4E14
Raw Field Data AC7 Angle
4E15
Raw Field Data AC8 Mag
4E17
Raw Field Data AC8 Angle
4E18
Raw Field Data DC1
4E19
Raw Field Data DC2
4E1A
Raw Field Data DC3
4E1B
Raw Field Data FCI States (2 items)
4E1D
Raw Field Data SI States
4E1E
Raw Field Data SI Test States
4E1F
Raw Field Data Brick ADC Temperature
4E20
Raw Field Data Brick Transceiver Temperature
4E21
Raw Field Data Brick Transceiver Voltage
4E22
Raw Field Data Brick Transceiver Current
4E23
Raw Field Data Brick Tx Power
4E24
Raw Field Data Brick Rx Power
4E25
Raw Field Data Brick Diagnostics (2 items)
4E27
Raw Field Data Local Transceiver Temperature
4E28
Raw Field Data Local Transceiver Voltage
4E29
Raw Field Data Local Transceiver Current
4E2A
Raw Field Data Local Tx Power
B-30
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
---
---
---
---
---
---
0 to 65535
---
1
---
---
---
0 to 0.001
A
0.001
0 to 0.1
degree
0.1
0 to 0.001
A
0.001
0 to 0.1
degree
0.1
0 to 0.001
A
0.001
0 to 0.01
degree
0.1
0 to 0.001
A
0.001
0 to 0.01
degree
0.1
0 to 0.001
A/V
0.001
0 to 0.01
degree
0.1
0 to 0.001
A/V
0.001
0 to 0.01
degree
0.1
0 to 0.001
A/V
0.001
0 to 0.01
degree
0.1
0 to 0.001
A/V
0.001
0 to 0.01
degree
0.1
0 to 0.001
V
0.001
0 to 0.001
V
0.001
0 to 0.001
V
0.001
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
degree
1
0 to 1
degree
1
0 to 0.01
V
0.01
0 to 1
mA
1
0 to 0.1
dBm
0.1
0 to 0.1
dBm
0.1
0 to 65535
---
1
0 to 1
degree
1
0 to 0.01
V
0.01
0 to 1
mA
1
0 to 0.1
dBm
0.1
APPENDIX B
FORMAT
DEFAULT
F202
" "
F202
" "
F001
0
F001
0
F003
0
F002
0
F003
0
F002
0
F003
0
F002
0
F003
0
F002
0
F003
0
F002
0
F003
0
F002
0
F003
0
F002
0
F003
0
F002
0
F002
0
F002
0
F002
0
F500
0
F500
0
F500
0
F002
0
F002
0
F001
0
F001
0
F002
0
F002
0
F500
0
F002
0
F001
0
F001
0
F002
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents