P R O G R A M M I N G T H E S Y S T E M
Sublevel 11.2 – Entering PIN-code:
Program immobilizer deactivation PIN-code using selected button or buttons. Enter the
first digit by pressing the previously selected button (pauses between presses should not
exceed 1 second). The base unit will confirm entering with red flash of
the second (third, fourth) digit by pressing the previously selected button. The base unit
will confirm entering of each digit with red flash of
Input the required number of digits (up to 4) and then press
system will confirm receiving of the secret validator code with long red flash of
indicator and will wait for confirmation of PIN-code.
Sublevel 11.3 - Confirmation of the PIN-code input:
Enter PIN-code again similarly to the procedure (
VALET
and press
button. The system will confirm correct PIN-code with red and green
LED
flashes of
indicator and will memorize PIN-code, and then the system will proceed
to programming mode awaiting level input. Incorrect confirmation is indicated with
LED
long red flash of
indicator, after that the system will return to programming mode.
Level 12 – Calibrating of fuel level
To control fuel level, make connection and configure the settings:
PANDORA ALARMSTUDIO.
• Setting is performed via
fuel level» item should be enabled in the settings, the factory setting of this input
(input settings) must be unselected.
• Make a connection in accordance with the «Fuel control input» scheme.
To define the current fuel level, calibration should be performed at least by two
points. In some cases fuel level calibration should be performed by all specified points
(for more exact definition). To calibrate fuel level, enter the programming mode and
VALET
press
button 12 times.
Calibrating of fuel level:
LED
Enter level 12 of programming,
indicator will be lit red. Select the desired
sub-level. To adjust zero value, switch on the ignition and save the setting. The total
number of sublevels are 12 (listed in the table). Enter the number of the desired
VALET
sublevel by pressing
button (press the button a number of times equals to
58
PANDORA DXL 1090L SERVICE-SECURITY SYSTEM
LED
indicator. Enter
LED
indicator.
VALET
button. The
LED
11.2 – E
PIN-
)
LEVEL
NTERING
CODE
«Use INP to control
P R O G R A M M I N G T H E S Y S T E M
the inputting digit; pauses between presses should not exceed 1 second).
Run the engine no less than in 1 minute, then press
be sent to the base unit. To save, press
canceled the calibration.
To exit the programming mode, enter sublevel 12 or press
than 12 times.
To reset all calibration values, proceed to sublevel 11 (do not switch on the
ignition). Reset confirmation is performed by pressing of
confirmation and exit the menu are performed by pressing
Sublevel
Assigning
I-12
0%
I-12.1
10%
I-12.2
20%
I-12.3
30%
I-12.4
40%
I-12.5
50%
I-12.6
60%
I-12.7
70%
I-12.8
80%
I-12.9
90%
I-12.10
100%
I-12.11
Reset all calibration values
I-12.12
Exit programming mode
USER MANUAL
VALET
button – the data will
button, pressing of
button will be
VALET
button more
button, exit without
VALET
button.
59