MSA G1 SCBA Operating Manual page 84

Niosh cbrn and nfpa 1981/1982 breathing apparatus
Hide thumbs Also See for G1 SCBA:
Table of Contents

Advertisement

Tagging In During Use
WARNING!
When using an ID Tag with the G1 power module, the ID Tag must touching the power module during
this process. If the tag is not, the PASS device can lockup. To fix the lockup, the batteries must be
removed for 30 seconds and then reinstalled.
Misuse can result in serious injury or death.
Using the Base Station with the Telemetry Module
The telemetry module is designed to work in conjunction with a remote base station unit. This base
station unit must be connected to a personal computer or notebook computer before use. Refer to the
®
MSA A2
Software Instructions (P/N 10162374) for more information.
WARNING!
Follow the PC or notebook computer manufacturer's recommendations for exposure to environmental
conditions to prevent damage to the system.
Failure to do so may cause system failure and the loss of monitoring capability on the PC or notebook
computer.
(1) Take the ID tag and place in hand.
(2) Place the tag in front of the RFID reader located on the
power module.
The RFID reader is located on the user's right hand side of
the backplate
(3) Press and hold BOTH green RESET buttons at the same
time until the RFID symbol appears.
(4) Keep the tag located at the power module until the blue bar
moves across the screen.
a)If the tag was successful, the information will be
displayed on the tag. If it is not, repeat the steps above
until the tag information is displayed on the screen.
G1 SCBA
Telemetry Module
84
US