Page 1
Operating Manual G1 Industrial SCBA NIOSH 42 CFR Part 84 Compliant Order No.: 10183894/01 MSAsafety.com...
Page 2
The warranties made by MSA with respect to the product are voided if the product is not installed and used in accordance with the instructions in this manual. Please protect yourself and your employees by following the instructions.
Refer to Users Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. Special or critical User’s Instructions and/or specific use limitations apply. Refer to user instruc- tions before donning. G1 Industrial SCBA...
OSHA Safety and Health Standards (29 CFR 1910) (see specifically Part 1910. 134), available from the Superintendent of Documents, U. S. Government Printing Office, Washington, DC 20402. Compressed Gas Association, Inc., 1725 Jefferson Davis Hwy., Suite 1004, Arlington, VA 22202. G1 Industrial SCBA...
Safety Regulations Contact Information In the event of a product concern, contact your local MSA authorized repair center or distributor, who will provide the necessary information to MSA for issue resolution. To report any serious concerns or to inquire about the products use the following contact information:...
Description Description The G1 Industrial SCBA - referred to hereafter as SCBA - is an open-circuit, pressure-demand, self- contained breathing apparatus (SCBA). Breathable air is supplied to the user from a self-contained compressed air cylinder. When the SCBA is equipped with an airline connection, the SCBA can be used as a supplied-air respi- rator (SAR).
The threaded and quick connect hose options include a connection positioned on the chest to improve hose maneu- verability and provide a hose separation point to simplify regulator removal for testing or repair. G1 Industrial SCBA...
(30, 45, 60 minutes) and one material option (carbon). The cylinder valve includes a large pressure gauge with a photo luminescent gauge face. The cylinder valve handwheel is available in two types (standard, locking). The locking handwheel requires a single G1 Industrial SCBA...
SCBA applications. The shoulder straps can be fitted with an optional chest strap to enhance wearing comfort. An optional regulator retainer is available to secure and protect the regu- lator when not in use. Optional Components Airline Connection G1 Industrial SCBA...
Page 12
The airline connection includes a quick connect that attaches to MSA approved air supply hoses. The airline connection includes a large sintered filter to remove particulate from the supplied air source. The airline connection includes a check valve to prevent loss of air through the hose when the cylinder valve is open (SCBA mode).
Page 13
ExtendAire II manifold. The ExtendAire II airline connection includes a quick connect that attaches to MSA approved air supply hoses. The ExtendAire II airline connection includes a large sintered filter to remove particulate from the supplied air source. The ExtendAire II connection includes a check valve to prevent loss of air through the hose when the cylinder valve is open (SCBA mode).
Page 14
ExtendAire II pouch, but is used to hold a Quick-Fill line or other items. The pouch is held securely closed by a combination of hook and loop fasteners and snaps, but can be opened using one hand. Spectacle Kit The spectacle kit provides the ability to mount prescription lenses inside the facepiece. G1 Industrial SCBA...
Use Quik Chek Kit (P/N 805078) to perform fit testing and following instructions provided with the kit. The fit test kit includes an adapter and instructions. Canister sold separately. Be sure the probe does not contact the face during fit testing. Failure to do so can result in false protection factor readings. G1 Industrial SCBA...
Functional Tests section, the SCBA must be removed from service and the condition must be checked and corrected by an MSA trained and certi- fied repair person before using. Failure to follow this warning can result in serious personal injury or death.
Inspect the pressure relief valve (if equipped). Ensure that the relief holes are clear and free of debris or other contaminants. Ensure that the pressure relief valve is properly secured. Inspect the hose connections. Ensure that the hoses are properly secured. G1 Industrial SCBA...
Department of Transportation (DOT) regulations. DOT regulations require that composite cylinders be retired from service after the fifteenth year. This does not include cylinder valve assem- blies that may be reused. Contact an MSA distributor or sales associate for more information regarding this policy.
4.10 Record Keeping Immediately following completion of the inspection, the date and initials of the designated inspector should be recorded. When the inspection data has been recorded, the SCBA is ready for functional tests. G1 Industrial SCBA...
If the SCBA does not function properly for all tests as described in the Functional Tests section, the SCBA must be removed from service and the condition must be checked and corrected by an MSA trained and certified repair person before using. Failure to follow this warning can result in serious personal injury or death.
290 psi or less. Further open the bypass valve to vent any remaining pressure in the system. Close the bypass valve (clockwise). If the bell alarm does not function properly, the SCBA must be removed from service. G1 Industrial SCBA...
If the SCBA does not function properly as described in this section, the SCBA must be removed from service and must be checked and corrected for proper operation by an MSA trained or certi- fied repairperson before using. This device may not seal properly with your face if you have a beard, gross sideburns or similar ...
SCBA Donning Procedure Slide the right arm through the right shoulder strap. Slide the left arm through the left shoulder strap. a) Check correct orientation of shoulder straps. b) Do not fasten the chest strap at this time. G1 Industrial SCBA...
Page 24
Most of the SCBA weight should be carried on the hips. b) The shoulder straps should remain loose. Attach the chest strap buckle (if equipped). Adjust the strap length as desired. a) Ensure the regulator hose is not caught under the strap. G1 Industrial SCBA...
Page 25
Stand up straight. Pull down on the shoulder strap pull tabs to tighten straps. Readjust the waist belt if necessary. Grasp the regulator and push the release buttons to remove the regulator from the regulator keeper (if equipped). Ensure that the bypass knob is fully closed (clockwise). G1 Industrial SCBA...
Page 26
DO NOT use the SCBA if the bell alarm fails to activate. The SCBA must be checked and corrected for proper operation by an MSA trained or certified technician before using. Failure to follow these warnings can result in serious personal injury or death.
Page 27
DO NOT use the SCBA if the pressure drops more than 100 psi in ten seconds. The SCBA must be repaired; otherwise, reduced service life may result. Failure to follow these warnings can result in serious personal injury or death. (13) Open the cylinder valve fully. G1 Industrial SCBA...
Spread the harness with both hands. Position the chin into the chin cup. Pull the head straps over your head. a) Ensure that the harness is sitting correctly and is not twisted. Adjust facepiece and tighten the straps firmly and evenly. G1 Industrial SCBA...
The facepiece must stay collapsed on face. b) Exhale. The exhalation valve should open and release the pressure inside the facepiece. If necessary retighten the straps. If the leak test fails the facepiece must not be used. G1 Industrial SCBA...
If the SCBA passes all tests, it is ready for use. These tests must be performed every time before entering a hazardous atmosphere. If the SCBA fails to meet any of the tests, the condition(s) must be corrected before using the SCBA. G1 Industrial SCBA...
proper servicing/maintenance has not been made or genuine MSA spare parts have not been used. Take into account the following factors which may affect the duration or the service life: the degree of physical activity of the user;...
This rapid pressure reduction causes air to expand and which creates a cooling effect. Although the surrounding temperature may be warmer than 32°F (0°C), the temperature inside the regulator may be lower. G1 Industrial SCBA...
After Use After Use Removing the SCBA Grasp the regulator release buttons. Push the release buttons and pull the regulator out of facepiece. Close the cylinder valve fully. G1 Industrial SCBA...
Page 34
(if equipped) to vent system pressure. Close the bypass valve. Stow the regulator in the regulator keeper (if equipped). Disconnect the chest strap buckle (if equipped). To remove the carrier and harness, disconnect the waist belt buckle. G1 Industrial SCBA...
Page 35
SCBA in the storage case or suitable storage location so that it can be easily reached for emergency use. (See storage instructions.) In situations where users share the SCBA, the regu- ® lator must be cleaned and disinfected using a Confidence Plus cleaning and disinfecting wipe to prevent cross contamination between users. G1 Industrial SCBA...
Loosen the head harness by pulling the buckles forward using your fingers. Grip the chin straps and pull the head harness forward over the head. Grip the front of the facepiece (as shown) and pull the facepiece away and down from the user. G1 Industrial SCBA...
® Confidence Plus Cleaning Solution (P/N 10009971) from MSA is recommended. It cleans and disin- fects in one operation. It retains its germicidal efficiency in hard water to inhibit the growth of bacteria. It will not deteriorate rubber, plastic, glass, or metal parts. Refer to the label to prepare the Confidence Plus Cleaning Solution.
Allow the facepiece to air dry. Do not dry the parts by placing them near a heater or in direct sunlight. Operate the exhalation valve by hand to be sure it works properly. Perform a tightness test before putting the facepiece back in service. G1 Industrial SCBA...
requirements of the Compressed Gas Association specification G-7.1 1989 for Quality Verification Level (grade) D air or equivalent specification. In fire service applications, MSA recommends breathing air quality in accordance with NFPA 1989. DO NOT drop the cylinder or bump the valve knob. An unsecured cylinder can become an airborne ...
If the cylinder valve is damaged, remove from service and return it to a MSA trained or certified repair technician. Inspect the internal threads and nipple of the male adapter to ensure it is not damaged and free of dirt and debris.
Close the bypass valve by turning the knob clockwise. Threaded connect: Unthread handwheel from cylinder valve assembly. Quick connect: Turn the handgrip fully clockwise until it stops - hold in posi- tion. G1 Industrial SCBA...
Before attaching the cylinder valve to the pressure reducer, check that the cylinder connection o-ring is present and free of damage. If the o-ring is damaged, it must be replaced before the SCBA is used. G1 Industrial SCBA...
Page 44
Inspect the cylinder to ensure that it is securely retained by the cylinder band. NOTE: If the cylinder feels loose, check the band length adjustment and latch engagement. Do not use the SCBA if the cylinder is not held securely in the carrier. G1 Industrial SCBA...
Close the valves on the cylinder and the filling system and remove the cylinder. Apply a leak solution to determine if there is any leakage between the cylinder and the valve. a) If there is no leakage, the cylinder is ready for use. G1 Industrial SCBA...
-65°F/-54°C (24ppm water vapor, normal). In fire service applications, MSA recommends breathing air quality in accordance with NFPA 1989. Pressures at the inlet of the Quick-Fill hose must not exceed that of the SCBA (2216 psi or 4500 psi).
Page 47
Remote Quick-Fill Operation NOTE: Rapid Intervention Teams should use a separate air supply such as MSA's RescueAire portable air supply system to fill the SCBA in an IDLH atmosphere. Connect the Quick-Fill hose to the secondary air supply. a) Turn the air supply on.
This will form a redundant seal. Open the cylinder valve and return to fresh air immediately. a) The dust cover prevents dirt, water, and debris from entering the fitting, and acts as a redun- dant seal. G1 Industrial SCBA...
Ensure the airline source is Quality Verification Grade D breathable air with inlet pressure between 70 - 110 PSIG. Air supply hose must be between 9.5" and 300 feet in length and supplied by MSA. A maximum of twelve sections of air hose may be connected together to create the airline.
NIOSH limitations for this device require that not more than 20 percent of the cylinder air be used during entry before connecting to the airline. 12.3 Use Of Combination Type Respirator, SCBA Mode For cylinder mode operation, see Donning and During Use sections. G1 Industrial SCBA...
If the airline supply should fail for any reason as detected by interrupted breathing, perform the following: Open the SCBA cylinder valve. Disconnect the airline quick connect fitting from the airline connection. If air is still not delivered to the facepiece, open the bypass valve. Immediately return to fresh air. G1 Industrial SCBA...
If the above measures cannot be followed or, to provide greater escape protection, use the Quick-Fill System. Use of Quick-Fill maintains approval while transfilling and does not exhibit the above hazards. Failure to follow this warning can result in serious personal injury or death. G1 Industrial SCBA...
WARNING! DO NOT install or attempt to use any hose assembly or fitting other than those supplied by MSA for the G1 ExtendAire II System. Misuse can result in serious injury or death. G1 Industrial SCBA...
(10) Replace the dust cap on the manifold fittings. WARNING! The receiver’s facepiece or regulator must be removed upon disconnection from the donor’s air supply. Misuse can result in serious injury or death from suffocation. G1 Industrial SCBA...
ExtendAire II airline connection through grommet in G1 Pouch (It may be necessary to feed dust cap through separately). This allows the connection to remain protected, but may be difficult for a solo user to connect/disconnect. G1 Industrial SCBA...
Ensure the airline source is Quality Verification Grade D breathable air with inlet pressure between 70 – 110 PSIG. Air supply hose must be between 9.5” and 300 feet in length and supplied by MSA. A maximum of twelve straight sections or six coiled sections of air hose may be connected together to create the airline.
Open the SCBA cylinder valve. Disconnect the airline quick connect fitting from the G1 ExtendAire II airline connector. If air is still not delivered to the facepiece, open the bypass valve. Immediately return to fresh air. G1 Industrial SCBA...
Push the top part of the frame into the lens. The faceblank has three rubber tabs to grab the frame. a) Place the frame in the middle of the lens with the smaller tabs grabbing the wire frame. G1 Industrial SCBA...
Page 59
Repeat step (4) on the opposite side. The lens frame can be adjusted up/down and in/out depending on the facial features. Don the facepiece and adjust to optimize visibility. G1 Industrial SCBA...
Always use original parts from MSA. Repairs and maintenance must be carried out only by authorized service centers or by MSA. Changes to devices or components are not permitted and will result in an unapproved configuration.
Failure to follow this warning can result in serious injury or death. MSA rubber products are protected by an anti-aging agent that can become visible as a light coating. This coating is harmless and can be removed during cleaning.
Page 62
For local MSA contacts, please visit us at MSAsafety.com Because every life has a purpose...