Button Functions; Integrated Thermal Imaging Camera; Turning Off The Control Module - MSA G1 SCBA Operating Manual

Niosh cbrn and nfpa 1981/1982 breathing apparatus
Hide thumbs Also See for G1 SCBA:
Table of Contents

Advertisement

9.6

Button Functions

RESET Buttons (green)
Both reset buttons have the same function, instead of pressing one button twice when
advised.
Pressing either button performs the following, depending on context:
Single Short Press to:
Activate the backlight and refresh the HUD (when in intermittent mode)
Toggle between primary and second screen
TIC Mode Only: Toggle between thermal image color palettes
Double Short Press to:
Reset PASS pre-alarm (or shake control module to reset)
Reset PASS full alarm
Confirm evacuation
Turn off device (when below 200 psig)
Clear primary alarms
Simultaneously press both buttons to:
Enter RFID Mode
ALARM Button
Activates PASS full alarm by pressing and holding the ALARM button. This will occur when either the
unit is OFF or ON.
9.7

Integrated Thermal Imaging Camera

(1)
Enter and exit thermal imaging mode via a single, long button press of either green RESET
button on the control module.
(2)
While in thermal imaging mode, toggle the palettes by single, short presses of either green
RESET button.
A total of 5 different color palettes can be added to the SCBA via custom configuration using the
A2 application software.
9.8

Turning OFF the Control Module

(1)
Upon returning to fresh air, close the cylinder valve completely and release all pressure from the
SCBA.
(2)
When the pressure falls below 200 psi, turn the control module off by double pressing the reset
button (green).
The shutdown sequence will display on the screen and the lights on the control module and the
power module will stop flashing.
G1 SCBA
Control Module
56
US