14.1 Instructions for Use

The G1 ExtendAire II System contains two quick-connection fittings, capable of connecting with both
male and female fittings on another user's manifold.
(1)
Quick-connect fittings require a single action to connect: Push the coupler firmly over the plug to
engage.
(2)
Quick-connect fittings require two actions to disconnect:
a)Push the two sides of the quick-connect towards each other. The plug should advance into the
coupler end an additional 1/8".
b)Slide the coupler's outer sleeve away from the plug. Pull the plug out of the coupler. Ensure
that the Quick-connect plug on the manifold black is protected by the supplied dust cap.
WARNING!
DO NOT install or attempt to use any hose assembly or fitting other than those supplied by MSA for
the G1 ExtendAire II System. Misuse can result in serious injury or death.

14.2 Inspection Before Use

Emergency Breathing Hose
(1)
Inspect the elbow connection to the G1 First Stage Regulator as
well as the hose connection to the elbow. Ensure that the hose is
properly secured.
(2)
Inspect the dust cover. Ensure that the cover is securely attached
to the male and female quick-connect fittings.
(3)
Ensure that the emergency breathing hose is coiled in the pouch
such that it is not twisted. Position the manifold end of the hose
toward the flap opening to ensure that it is accessible in an emer-
gency breathing situation.
G1 SCBA
G1 ExtendAire II EBSS
US
75