Facepiece Donning Procedure - MSA G1 SCBA Operating Manual

Niosh cbrn and nfpa 1981/1982 breathing apparatus
Hide thumbs Also See for G1 SCBA:
Table of Contents

Advertisement

WARNING!
DO NOT use the SCBA if the pressure reducer warning signal fails to sound or fails to continuously
sound down to pressures of 200 psi, or if the control module or HUD fails to light properly.
Failure to follow these warnings can result in serious personal injury or death.
6.4

Facepiece Donning Procedure

The facepiece is either carried using the neck strap in front of the chest or using the clip on the
shoulder strap. To ensure protection from dirt and debris, ensure the facepiece opening is towards the
user's body.
(1)
Spread the harness with both hands.
(2)
Position the chin into the chin cup.
(3)
Pull the head straps over your head.
a)Ensure that the harness is sitting correctly and is not
twisted.
G1 SCBA
Donning
US
36