Removing The Facepiece - MSA G1 SCBA Operating Manual

Niosh cbrn and nfpa 1981/1982 breathing apparatus
Hide thumbs Also See for G1 SCBA:
Table of Contents

Advertisement

NOTE:
Be sure to replace the cylinder with a fully charged one. Complete Inspection, Cleaning and
Disinfecting Procedures outlined in this manual. Ensure that the complete SCBA is clean and dry.
Ensure that facepiece head harness straps and harness adjustment straps are fully extended. Place
the complete SCBA in the storage case or suitable storage location so that it can be easily reached
for emergency use. (See storage instructions.) In situations where users share the SCBA, the regu-
lator must be cleaned and disinfected using a Confidence Plus cleaning and disinfecting wipe to
prevent cross contamination between users.

10.2 Removing the Facepiece

(10) Slip the left arm out of the shoulder strap first, then remove
the harness.
(1)
Loosen the head harness by pulling the buckles forward
using your fingers.
(2)
Grip the chin straps and pull the head harness forward over
the head.
(3)
Grip the front of the facepiece (as shown) and pull the
facepiece away and down from the user.
G1 SCBA
After Use