Option 4: Oscillating Mode
Oscillating mode shows the pressure status on an interval basis. The LEDs cycle from a low light level
to a high light level periodically. The LEDs are always on and the brightness changes over time during
the pressure ranges of Segment 1 and Segment 2. Once Segment 3 is reached, the LEDs flash for
30 seconds before going back to oscillating until Segment 4 is reached. Once Segment 4 is reached
the LEDs activate and stay flashing until the unit is shutdown.
8.2

G1 HUD Alarm Status

The status LEDs alert the user to primary and second alarms on the SCBA. These status LEDs use
three icons:
battery icon,
running man icon
caution triangle.
Alarm
PASS Pre-Alarm
PASS Full Alarm
PASS Manual Alarm
Electronics Failure
Primary Thermal Alarm
(Optional)
Segment 1: 75 to 100 %
Oscillating
Segment 2: 50 to 74 %
Oscillating
Segment 3: 36 to 49 %
Flashing 30 sec, Oscillating
Segment 4: 0 to 35 %
Flashing continuously
Illuminated Icon
G1 SCBA
G1 Heads-Up Display (HUD)
Icon shown
Red Flashing*
Red Solid
Red Solid
Red Flashing*
Red Flashing*