Page 2
The Declaration of Conformity can be found under the following link: https://MSAsafety.com/DoC. MSA is a registered trademark of MSA Technology, LLC in the US, Europe and other Countries. For all other trademarks visit https://us.msasafety.com/Trademarks. MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil-Jona...
Removing the Mask Spectacle Kit Cleaning, Disinfection Cleaning/Disinfection of the Filter Adapter Cleaning/Disinfection of the Helmet Cleaning, Disinfection Preparing the Mask for Cleaning or Disinfection Suitable Cleaning and Disinfection Procedures Maintenance Maintenance Instructions Maintenance Intervals G1-H Mask - Positive Pressure...
Page 4
Applicable Helmets MSA F1 Helmets Ordering Information Exploded View Accessories ATO Code 9.3.1 Europe Helmet Mask PC (Standard lens "P") 9.3.2 Europe Helmet Mask PC (Anti-scratch lens "H") 9.3.3 Europe Helmet Mask APEC (Anti-fog lens "A") G1-H Mask - Positive Pressure...
1 Safety Regulations Safety Regulations Correct Use The G1-H Mask - Positive Pressure - hereafter called mask - is a respiratory interface with positive connection including head protection. They are not complete respiratory protective devices by themselves, but serve as facepieces [DIN 58610:2014] for use with compressed air breathing apparatus of the G1 series and respiratory filters.
1 Safety Regulations Liability Information MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims, warranties also as guarantees made by MSA with respect to the product are voided if it is not used, serviced, or maintained in accordance with the instructions in this manual.
The mask is available with different head harnesses and different component housings. Figure 1 Overview mask/helmet combination Faceblank Inlet valve Helmet adapter, right Component housing Helmet adapter, left Rubber neck strap Lens Nomex (textile) neck strap Nosecup G1-H Mask - Positive Pressure...
EN 148-1 can be attached to the mask. The instructions for use of the respiratory filters have to be regarded, including any information regarding the use in potentially explosive atmospheres. G1-H Mask - Positive Pressure...
Harmonized/designated standard CE-marking with notified body number (DEKRA, Zertifizierungsstelle Dinnendahlstr. 9, 44809 Bochum) UKCA-marking with approved body number (BSI Assurance UK Ltd, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes, MK5 8PP, United Kingdom) Part number/ATO code G1-H Mask - Positive Pressure...
Knowlhill, Milton Keynes, MK5 8PP, United Kingdom The Declaration of Conformity can be found under the following link: https://MSAsafety.com/DoC. ATEX Categories The lowest ATEX class of a part sets the limit for the complete device. G1-H Mask - Positive Pressure I M1 Rubber II 1G IIC...
2 Description G1-H Mask - Positive Pressure II 1D I M1 II 1G IIB Textile HMC II 1D I M1 Filter Adapter for Fixed Push-to-Connect II 1G IIC II 1D Push-To-Connect I M1 Connector pieces M45x3 II 1G IIC II 1D...
Page 12
ATO configuration K-(S/1 or M/1 or L/1)-(S or M or L)-(4 or E)-(O or C or R)-(P or M or E or U or V or W), see chapter 9.3 The Operating Manual M1 Modular SCBA System must be observed. G1-H Mask - Positive Pressure...
Adjust the helmet according to the helmet’s operating manual. Grip the helmet with both hands with the chinstrap open. Pull the helmet from the forehead over the head. Close and slightly tighten the chin strap. G1-H Mask - Positive Pressure...
Donning the Mask WARNING! In order to guarantee a proper fit for those wearing glasses, the G1-H Mask - Positive Pressure spectacle kit must be worn since ordinary glasses cannot be worn under the mask. Failure to follow this warning can result in serious personal injury or death.
Remove the mask to the front. Open chin strap and remove the helmet. NOTE: Do not re-tighten the screws! Moving of Helm Flex adapters/brackets is normal after use. G1-H Mask - Positive Pressure...
Push the top part of the frame into the lens. The faceblank has three rubber tabs to grab the frame. Place the frame in the middle of the lens with the smaller tabs grabbing the wire frame. G1-H Mask - Positive Pressure...
Page 17
Repeat step (3) on the opposite side. The frame for the spectacles can be adjusted up/down and in/out depending on the facial features. Don the mask and adjust to optimize visibility. G1-H Mask - Positive Pressure...
For online version scan the QR code or go to the product page on www.MSAsafety.com. The power supply for the HUD (if applicable) is not part of the G1-H Mask - Positive Pressure and is therefore not damaged during cleaning.
This product should be regularly checked and serviced by trained specialists. Inspection and service records must be maintained. Always use original parts from MSA. Repairs and maintenance must be carried out only by authorized service centres or by MSA. Changes to devices or components are not permitted and will result in loss of approval.
Push-to-Connect AS/M45x3/ESA Insert the delatching tool (10204283-SP) into the tabbed slot with below the connector. Leverage the tool down to unlock until it unsnaps. Rotate the cover off of the facepiece. G1-H Mask - Positive Pressure...
Press the cover over the front of the component housing assembly until the locking tab snaps into place with an audible click. NOTE: Apply even pressure on both sides of the cover to snap the locking tab securely onto the component housing assembly. G1-H Mask - Positive Pressure...
Remove the exhalation valve. Discard if the valve is torn, tacky, or otherwise damaged. NOTE: Be careful not to damage the fork seats or valve seat. If either is damaged, replace the component housing. G1-H Mask - Positive Pressure...
NOTE: Ensure the valve stem is inserted into the center slot. Fit the spring over the ring of the exhalation valve. Align the forks on the flat surface of the component housing and slide forward until each fork snaps into place. G1-H Mask - Positive Pressure...
Perform a tightness test (→ Tightness Test of the Mask The testing of the masks for tightness is performed using an applicable MSA test device (i. e. SmartCHECK) in accordance with the relevant operating manual. Fit mask tight onto the test device.
6 Maintenance Helmet Maintenance For detailed information about helmet maintenance refer to the helmet operating manual. G1-H Mask - Positive Pressure...
Failure to follow this warning can result in serious personal injury or death. For the safekeeping of the mask the mask container should be used. MSA rubber products are protected by an anti-aging agent that can become visible as a light coating. This coating is harmless and can be removed during cleaning.
Ex ia IIIC T135 °C .. T200 °C Db • Flexible microphone II 2G Ex ib IIC T4 Gb headset Communication If the colors of the connector are Accessories • Bone conductive headset identical, the corresponding combination is ATEX compliant. • Headset G1-H Mask - Positive Pressure...
Page 29
Yellow, orange, silver Ex I M1, Ex II 1D, Ex II 1G IIC Helmets F1E No use of mask-helmet combinations with F1E in potentially explosive atmospheres yellow blue Color of the shell black grey green fluorescent orange G1-H Mask - Positive Pressure...
Page 30
No use of mask-helmet combinations with F1E in potentially explosive atmospheres fluorescent yellow photoluminescent white with black comb with or without ocular visor (GA1046A) Gold version (GA1055C) Face shield Clear version (GA1055B) Aluminized (GA 1106R) Neck curtain Wool/Nomex black (GA1106P) G1-H Mask - Positive Pressure...
For this product, order numbers have been replaced by an ATO (Assemble To Order) code. To order a G1-H Mask - Positive Pressurewith a medium sized faceblank, a medium nosecup, rubber neck strap and Push-To-Connect connector piece, the ATO code would be...
E - ESA ("M"+ ESA-Adapter) L/I - Large Hycar S - Small 0 - None 2 - Fixed Push-To-Connect H - Helmet Mask Adapter L/2 - Large R - Rubber P - Push to Connect Sensitive Medium G1-H Mask - Positive Pressure...
L/2 - Large H - Helmet R - Rubber P - Push to Connect Sensitive Medium Mask Adapter M - M45 x 3 H - Cloth L - Large (MHC) E - ESA ("M"+ ESA-Adapter) G1-H Mask - Positive Pressure...
Page 37
9 Ordering Information G1-H Mask - Positive Pressure...
Page 38
For local MSA contacts, please visit us at MSAsafety.com...