Overview Of Units - Mitsubishi Electric PUMY-P112VKM3 Technical & Service Manual

City multi series split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P112VKM3:
Table of Contents

Advertisement

2

OVERVIEW OF UNITS

2-1. UNIT CONSTRUCTION
Outdoor unit
Capacity
Applicable
indoor unit Number of units
Total system wide capacity
Cassette Ceiling
Model
2 by 2 4-way flow 2-way flow 1-way flow
PLFY-P PLFY-P PLFY-P PMFY-P
Capacity
15VFM-E1
15
20VFM-E1 20VBM-E 20VLMD-E 20VBM-E
20
25VFM-E1 25VBM-E 25VLMD-E 25VBM-E
25
32VFM-E1 32VBM-E 32VLMD-E 32VBM-E
32
40VFM-E1 40VBM-E 40VLMD-E 40VBM-E
40
50VFM-E1 50VBM-E 50VLMD-E
50
63VBM-E 63VLMD-E
63
71
80VBM-E 80VLMD-E
80
100VBM-E 100VLMD-E
100
125VBM-E 125VLMD-E
125
140
Decorative panel
Name
Model number
Remote
controller
Functions
*1. PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*2. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110% (100%
in case of heating below −5:.
*3. When connecting PWFY series (Note that the connection is not allowed inside EU countries.)
• Only 1 PWFY-P100VM-E-AU can be connected. PWFY-P200VM-E-AU and PWFY-P100VM-E-BU cannot be connected.
• T he PWFY unit cannot be the only unit connected to an outdoor unit. Select an indoor unit so that the total rated capacity of the indoor
units, excluding the PWFY unit, is 50 to 100% of the outdoor unit capacity.
*4. When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
*5. Authorized connectable indoor units are as follows;
PUMY-P112: PEFY-P25VMA3-E × 2 + PEFY-P32VMA3-E × 2
PUMY-P125: PEFY-P32VMA3-E × 4
PUMY-P140: PEFY-P32VMA3-E × 3 + PEFY-P40VMA3-E × 1
*6. Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
OCH632A
4HP
PUMY-P112VKM3(-BS)
PUMY-P112YKM(E)3(-BS)
1 to 9 unit
CMY-Y62-G-E
Branching pipe
Branch header
components
(2 branches)
Ceiling
Wall
Concealed
Mounted
PEFY-P
PKFY-P PCFY-P PFFY-P
15VMS1(L)-E 15VBM-E
20VMS1(L)-E
20VMA(L)-E
20VBM-E
20VMR-E-L/R
25VMS1(L)-E
25VMA(L)-E
25VBM-E
25VMR-E-L/R
25VMA3-E *
5
32VMS1(L)-E
32VMA(L)-E
32VHM-E
32VMR-E-L/R
32VMA3-E *
5
40VMS1(L)-E
40VMA(L)-E
40VHM-E 40VKM-E
40VMH-E
5
40VMA3-E *
50VMS1(L)-E
50VMA(L)-E
50VHM-E
50VMH-E
63VMS1(L)-E
63VMA(L)-E
63VKM-E 63VKM-E 63VLEM-E
63VMH-E
71VMA(L)-E
71VMH-E
80VMA(L)-E
80VMH-E
100VMA(L)-E
100VKM-E 100VKM-E
100VMH-E
125VMA(L)-E
125VMH-E
140VMA(L)-E
140VMH-E
M-NET remote controller
PAR-F27MEA-E,
PAR-U02MEDA
• A handy remote controller for use in
conjunction with the Melans centralized
management system.
• Addresses must be set.
5HP
PUMY-P125VKM3(-BS)
PUMY-P140VKM3(-BS)
PUMY-P125YKM(E)3(-BS)
PUMY-P140YKM(E)3(-BS)
Type 15 to Type 140
1 to 10 unit
50 to 130% of outdoor unit capacity *2 *3
CMY-Y64-G-E
CMY-Y68-G-E
Branch header
Branch header
(4 branches)
(8 branches)
Floor standing
Ceiling concealed
Ceiling
Suspended
Exposed Concealed Fresh air *
PFFY-P
PEFY-P
20VLEM-E
20VLRM-E
20VKM-E2
20VLRMM-E
25VLEM-E
25VLRM-E
25VKM-E2
25VLRMM-E
32VLEM-E
32VLRM-E
32VKM-E2
32VLRMM-E
40VLEM-E
40VLRM-E
40VKM-E2
40VLRMM-E
50VLRM-E
50VLEM-E
50VLRMM-E
63VLRM-E
63VLRMM-E
80VMH-E-F 80VM-E
125VKM-E
140VMH-E-F
MA remote controller
PAR-21MAA, PAR-31/32MAA
PAR-W21MAA(when using PWFY)
• Addresses setting is not
necessary.
5
6HP
1 to 12 unit
Lossnay
Air to Water
1
3
Built-in
unit
*
6
PDFY
GUF*
PWFY-P
20VM-E
25VM-E
32VM-E
40VM-E
50VM-E 50RD(H)4
63VM-E
71VM-E
100VM-E1-AU
100VM-E 100RD(H)4
100VM-E2-AU
125VM-E
M series remote
CONNECTION KIT
PAC-LV11M-J
M series indoor unit *
4
MSZ-GE Series
MSZ-SF Series
MSZ-EF Series
MSZ-FH Series
MFZ-KJ Series
controller