Overview Of Units - Mitsubishi Electric CITY MULTI PUMY-P200YKM2R2 Technical & Service Manual

Split-type, heat pump air conditioners
Table of Contents

Advertisement

2

OVERVIEW OF UNITS

2-1. SYSTEM CONSTRUCTION
Outdoor unit
Capacity
Applicable
Number of units
indoor unit
Total system capacity range
Branching pipe
components
Model
Cassette Ceiling
4-way flow
2 by 2
PLFY-P PLFY-P PLFY-M PLFY-
Capacity
10
15VFM-E1
15
20VFM-E1 20VEM-E 20VEM-E
20
25VFM-E1 25VEM-E 25VEM-E
25
32VFM-E1 32VEM-E 32VEM-E
32
40VFM-E1 40VEM-E 40VEM-E
40
50VFM-E1 50VEM-E 50VEM-E
50
63VEM-E 63VEM-E 63VEM-E 63VLMD-E
63
71
80VEM-E 80VEM-E
80
100VEM-E 100VEM-E
100
125VEM-E 125VEM-E
125
140
200
Note: Only for R1//R2 models: PEFY-P·VMA(L)-E3, PKFY-P·VLM-E
Only for R2 models:PLFY-M·VEM, PEFY-M·VMA(L), PEFY-P·VMHS-E-F, PFFY-P·VCM
Name
Model number
Remote
controller
Functions
*
1
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
*
2
When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110%.
*
3
When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
*
4
Authorized connectable indoor units are only as follows; PUMY-P200 : PEFY-P40VMA3 × 2 + PEFY-P63VMA3 × 2
*
5
Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-43SMF-E, PZ-52SF-E, PZ-60DR-E)
*
6
Authorized connectable indoor units are only as follows; PLFY-EP63VEM-E × 3
OCH675E
CMY-Y62-G-E
Branch header
(2 branches)
Ceiling
Concealed
2-way flow 1-way flow
PLFY-P PMFY-P
PEFY-P
EP *
6
15VMS1(L)-E
20VMS1(L)-E
20VMA(L)-E
20VLMD-E 20VBM-E
20VMA(L)-E(2/3)
20VMR-E-L/R
25VMS1(L)-E
25VMA(L)-E
25VLMD-E 25VBM-E
25VMA(L)-E(2/3)
25VMR-E-L/R
32VMS1(L)-E
32VMA(L)-E
32VLMD-E 32VBM-E
32VMA(L)-E(2/3)
32VMR-E-L/R
40VMS1(L)-E
40VMA(L)-E
40VLMD-E 40VBM-E
40VMA(L)-E(2/3)
40VMA3-E*
40VMHS-E
50VMS1(L)-E
50VMA(L)-E
50VLMD-E
50VMA(L)-E(2/3)
50VMHS-E
63VMS1(L)-E
63VMA(L)-E
63VMA(L)-E(2/3)
63VMA3-E*
63VMHS-E
71VMA(L)-E
71VMA(L)-E(2/3)
71VMHS-E
80VMA(L)-E
80VLMD-E
80VMA(L)-E(2/3)
80VMHS-E
100VMA(L)-E
100VLMD-E
100VMA(L)-E(2/3)
100VMHS-E
125VMA(L)-E
125VLMD-E
125VMA(L)-E(2/3)
125VMHS-E
140VMA(L)-E
140VMA(L)-E(2/3)
140VMHS-E
200VMHS-E
M-NET remote controller
PAR-U02MEDA
• A handy remote controller for use
in conjunction with the Melans
centralized management system.
• Addresses must be set.
8HP
PUMY-P200YKM2
PUMY-P200YKM2-BS
Type 10 to Type 200
1 to 12 unit
50 to 130% of outdoor unit capacity
CMY-Y64-G-E
Branch header
(4 branches)
Ceiling
Wall
Suspended
Mounted
Exposed Concealed Fresh
PEFY-M
PKFY-P PCFY-P PFFY-P PFFY-P PEFY-P GUF *
10VLM-E
15VLM-E
20VLEM-E
20VMA(L)-A 20VLM-E
20VKM-E2
20VCM-E
25VLEM-E
25VMA(L)-A 25VLM-E
25VKM-E2
25VCM-E
32VLEM-E
32VMA(L)-A 32VLM-E
32VKM-E2
32VCM-E
40VLEM-E
40VMA(L)-A 40VLM-E 40VKM-E
40VKM-E2
4
40VCM-E
50VLEM-E
50VMA(L)-A 50VLM-E
50VCM-E
63VLEM-E
63VMA(L)-A 63VKM-E 63VKM-E
63VCM-E
4
71VMA(L)-A
80VMA(L)-A
100VMA(L)-A 100VKM-E 100VKM-E
125VMA(L)-A
125VKM-E
140VMA(L)-A
MA remote controller
PAR40MAA
• Addresses setting is not
necessary.
6
2
*
CMY-Y68-G-E
Branch header
(8 branches)
Ceiling
Floor standing
concealed
Lossnay
1
air *
5
20VLRM-E
20VLRMM-E
25VLRM-E
25VLRMM-E
32VLRM-E
32VLRMM-E
40VLRM-E
40VLRMM-E
50VLRM-E
50RD(H)4
50VLRMM-E
63VLRM-E
63VLRMM-E
100RD(H)4
200VMHS-
E-F
CONNECTION KIT
PAC-LV11M-J