4-3. STANDARD OPERATION DATA (REFERENCE DATA)
Operation
Indoor
Ambient
temperature
Outdoor
No. of connected units
Indoor unit
No. of units in operation
Model
Operating
conditions
Main pipe
Piping
Branch pipe
Total pipe length
Fan speed
Amount of refrigerant
Electric current
Outdoor unit
Voltage
Compressor frequency
LEV
Indoor unit
opening
Pressure
High pressure/Low pressure
Discharge
Heat exchanger outlet
Outdoor
unit
Accumulator inlet
Temp. of
each section
Compressor inlet
LEV inlet
Indoor unit
Heat exchanger inlet
OCH632A
PUMY-P112VKM3(-BS)
PUMY-P112YKM3(-BS)
PUMY-P112YKME3(-BS)
DB/
27°C/19°C
20°C/—
WB
35°C
7°C/6°C
2
Unit
2
50 x 1/63 x 1
5
m
2.5
10
Hi
kg
7.2
A
16.17/5.26
17.38/5.67
V
230/400
Hz
67
69
Pulse
357
421
MPa G
2.70/0.94
2.86/0.70
67.0
71.9
40.2
2.0
8.7
1.0
°C
10.7
1.3
18.9
32.4
12.3
55.5
17
PUMY-P125VKM3(-BS)
PUMY-P125YKM3(-BS)
PUMY-P125YKME3(-BS)
27°C/19°C
20°C/—
35°C
7°C/6°C
2
2
63 × 2
5
2.5
10
Hi
7.2
21.67/7.12
21.91/7.22
230/400
84
86
447
525
2.86/0.88
2.87/0.67
69.7
72.1
40.8
1.3
8.0
0.2
9.1
0.1
17.7
33.0
11.1
55.7
PUMY-P140VKM3(-BS)
PUMY-P140YKM3(-BS)
PUMY-P140YKME3(-BS)
27°C/19°C
20°C/—
35°C
7°C/6°C
2
2
63 x 1/80×1
5
2.5
10
Hi
7.2
25.84/8.58
25.54/8.48
230/400
96
96
511
586
2.95/0.85
2.95/0.65
70.7
73.2
43.7
0.9
5.6
−0.6
7.8
−0.7
17.0
33.4
10.4
56.8

Hide quick links: